Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Spectral retrieval techniques for high-resolution Fourier-transform micro-spectrometers

dc.contributor.authorHerrero-Bermello, Alaine
dc.contributor.authorVillafranca Velasco, Aitor
dc.contributor.authorPodmore, Hugh
dc.contributor.authorCheven, Pavel
dc.contributor.authorSchmid, Jens H.
dc.contributor.authorJanz, Siegfried
dc.contributor.authorCalvo Padilla, María Luisa
dc.contributor.authorXu, Dan-Xia
dc.contributor.authorScott, Alan
dc.contributor.authorLee, Regina
dc.date.accessioned2023-06-17T22:36:10Z
dc.date.available2023-06-17T22:36:10Z
dc.date.issued2018
dc.description© 2018 SPIE. Conference on Fiber Lasers and Glass Photonics - Materials through Applications (2018. Strasbourg, Francia) We acknowledge the support from the National Research Council Canada, the Canadian Space Agency (CSA), and the Natural Sciences and Engineering Research Council of Canada (NSERC), by the Spanish “Ministerio de Economía y Competitividad” through projects TEC2015-71127-C2-1-R and TEC2015-71127-C2-2-R, by the “Comunidad de Madrid” through program SINFOTON-CM S2013/MIT-2790, and EURAMET through projects JRP-i22 14IND13 Photind and project 734331-H2020-MSCA-RISE:SENSIBLE. The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union. This work was also supported in part by the EMPIR initiative, which is co-funded by the European Union's Horizon 2020 research and innovation programme and the EMPIR Participating States. Aitor V. Velasco acknowledges support from "Ministerio de Economía y Competitividad" through grant FJCI-2014-22836.
dc.description.abstractSpatial heterodyne Fourier transform (SHFT) spectroscopy is based on simultaneous interferometric measurements implementing linearly increasing optical path differences, hence circumventing the need for mechanical components of traditional Fourier transform spectroscopy schemes. By taking advantage of the high mode confinement of the Silicon-on-Insulator (SOI). platform, great interferometric lengths can be implemented in a reduced footprint, hence increasing the resolution of the device. However, as resolution increases, spectrometers become progressively more sensitive to environmental conditions, and new spectral retrieval techniques are required. In this work, we present several software techniques that enhance the operation of high-resolution SHFT micro-spectrometers. Firstly, we present two techniques for mitigating and correcting the effects of temperature drifts, based on a temperature-sensitive calibration and phase errors correction. Both techniques are demonstrated experimentally on a 32 Mach-Zehnder interferometers array fabricated in a Silicon-on-insulator chip with microphotonic spirals of linearly increasing length up to 3.779 cm. This configuration provides a resolution of 17 pm in a compact device footprint of 12 mm(2). Secondly, we propose the application of compressive-sensing (CS) techniques to SHFT micro-spectrometers. By assuming spectrum sparsity, an undersampled discrete Fourier interferogram is inverted using l1-norm minimization to retrieve the input spectrum. We demonstrate this principle on a subwavelength-engineered SHFT with 32 MZIs and a 50 pm resolution. Correct retrieval of three sparse input signals was experimentally demonstrated using data from 14 or fewer MZIs and applying common CS reconstruction techniques to this data.
dc.description.departmentDepto. de Óptica
dc.description.facultyFac. de Ciencias Físicas
dc.description.refereedTRUE
dc.description.sponsorshipUnión Europea. H2020
dc.description.sponsorshipMinisterio de Economía y Competitividad (MINECO)
dc.description.sponsorshipComunidad de Madrid
dc.description.sponsorshipEURAMET
dc.description.sponsorshipEMRP within EURAMET
dc.description.sponsorshipEMPIR
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/50581
dc.identifier.doi10.1117/12.2306130
dc.identifier.issn0277-786X
dc.identifier.officialurlhttp://dx.doi.org/10.1117/12.2306130
dc.identifier.relatedurlhttps://www.spiedigitallibrary.org
dc.identifier.urihttps://hdl.handle.net/20.500.14352/18682
dc.journal.titleProceedings of SPIE
dc.language.isoeng
dc.publisherSPIE - International Society for Optical Engineering
dc.relation.projectIDSENSIBLE (734331)
dc.relation.projectID(TEC2015-71127-C2-1-R; TEC2015-71127-C2-2-R)
dc.relation.projectIDSINFOTON-CM (S2013/MIT-2790)
dc.relation.projectIDJRP-i22 14IND13,
dc.relation.projectIDFJCI-2014-22836
dc.rights.accessRightsopen access
dc.subject.cdu535
dc.subject.keywordSpatial heterodyne spectrometer
dc.subject.keywordChip
dc.subject.keywordGratings
dc.subject.ucmÓptica (Física)
dc.subject.unesco2209.19 Óptica Física
dc.titleSpectral retrieval techniques for high-resolution Fourier-transform micro-spectrometers
dc.typejournal article
dc.volume.number10683
dspace.entity.typePublication
relation.isAuthorOfPublicatione2846481-608d-43dd-a835-d70f73a4dd48
relation.isAuthorOfPublication.latestForDiscoverye2846481-608d-43dd-a835-d70f73a4dd48

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
CalvoML132libre.pdf
Size:
1019.61 KB
Format:
Adobe Portable Document Format

Collections