Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Comparison of the Surface Roughness of CAD/CAM Metal-Free Materials Used for Complete-Arch Implant-Supported Prostheses: an In Vitro Study

dc.contributor.authorMory, Nataly
dc.contributor.authorCascos Sánchez, Rocío
dc.contributor.authorCelemín Viñuela, María Del Pilar Alicia
dc.contributor.authorGómez Polo, Cristina
dc.contributor.authorAgustín Panadero, Rubén
dc.contributor.authorGómez Polo, Miguel Ángel
dc.date.accessioned2024-12-10T12:37:57Z
dc.date.available2024-12-10T12:37:57Z
dc.date.issued2023-11-13
dc.description2023 Descuento MDPI
dc.description.abstractThe roughness of the intra-oral surfaces significantly influences the initial adhesion and the retention of microorganisms. The aim of this study was to analyze the surface texture of four different CAD-CAM materials (two high-performance polymers and two fifth-generation zirconia) used for complete-arch implant-supported prostheses (CAISPs), and to investigate the effect of artificial aging on their roughness. A total of 40 milled prostheses were divided into 4 groups (n = 10) according to their framework material, bio.HPP (B), bio.HPP Plus (BP), zirconia Luxor Z Frame (ZF), and Luxor Z True Nature (ZM). The areal surface roughness “Sa” and the maximum height “Sz” of each specimen was measured on the same site after laboratory fabrication (lab as-received specimen) and after thermocycling (5–55 °C, 10,000 cycles) by using a noncontact optical profilometer. Data were analyzed using SPSS version 28.0.1. One-way ANOVA with multiple comparison tests (p = 0.05) and repeated measures ANOVA were used. After thermocycling, all materials maintained “Sa” values at the laboratory as-received specimen level (p = 0.24). “Sz” increased only for the zirconia groups (p = 0.01). B-BP exhibited results equal/slightly better than ZM-ZF. This study provides more realistic surface texture values of new metal-free materials used in real anatomical CAISPs after the manufacturing and aging processes and establishes a detailed and reproducible measurement workflow.
dc.description.departmentDepto. de Odontología Conservadora y Prótesis
dc.description.facultyFac. de Odontología
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationMory N, Cascos R, Celemín-Viñuela A, Gómez-Polo C, Agustín-Panadero R, Gómez-Polo M. Comparison of the Surface Roughness of CAD/CAM Metal-Free Materials Used for Complete-Arch Implant-Supported Prostheses: An In Vitro Study. Biomedicines. 2023 Nov 13;11(11):3036. doi: 10.3390/biomedicines11113036
dc.identifier.doi10.3390/biomedicines11113036
dc.identifier.essn2227-9059
dc.identifier.officialurlhttps://doi.org/10.3390/biomedicines11113036
dc.identifier.pmid38002036
dc.identifier.relatedurlhttps://www.mdpi.com/2227-9059/11/11/3036
dc.identifier.relatedurlhttps://pubmed.ncbi.nlm.nih.gov/38002036/
dc.identifier.urihttps://hdl.handle.net/20.500.14352/112324
dc.issue.number11
dc.journal.titleBiomedicines
dc.language.isoeng
dc.page.initial3036
dc.publisherMDPI
dc.rightsAttribution 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subject.cdu616.314-089.843
dc.subject.cdu616.314-089.28
dc.subject.cdu615.46
dc.subject.keywordSurface roughness
dc.subject.keywordSurface texture
dc.subject.keywordCAD/CAM
dc.subject.keywordHigh-performance polymers
dc.subject.keywordPEEK
dc.subject.keywordZirconia
dc.subject.keywordThermocycling
dc.subject.keywordComplete-arch implant-supported prostheses
dc.subject.ucmOdontología (Odontología)
dc.subject.ucmPrótesis dental
dc.subject.ucmMateriales dentales
dc.subject.unesco3213.13 Ortodoncia-Estomatología
dc.titleComparison of the Surface Roughness of CAD/CAM Metal-Free Materials Used for Complete-Arch Implant-Supported Prostheses: an In Vitro Study
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number11
dspace.entity.typePublication
relation.isAuthorOfPublication679037d0-9151-469f-b376-82e430ee7e1d
relation.isAuthorOfPublication778fca4c-b24e-4063-9a95-b569ae54dfc2
relation.isAuthorOfPublication778fca4c-b24e-4063-9a95-b569ae54dfc2
relation.isAuthorOfPublication9700c70b-34f2-4d6a-8e12-92587c9186fb
relation.isAuthorOfPublication.latestForDiscovery679037d0-9151-469f-b376-82e430ee7e1d

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Biomedicines. 2023 Nov 13;11(11):3036.pdf
Size:
3.47 MB
Format:
Adobe Portable Document Format
Description:
Comparison of the Surface Roughness of CAD/CAM Metal-Free Materials Used for Complete-Arch Implant-Supported Prostheses: An In Vitro Study

Collections