Comparison of the Hemodynamic Performance of the Balloon-expandable SAPIEN 3 Versus Self-expandable Evolut R Transcatheter Valve: A Case-matched Study

dc.contributor.authorEnríquez Rodríguez, Eduardo
dc.contributor.authorAmat Santos, Ignacio J.
dc.contributor.authorJiménez Quevedo, Pilar
dc.contributor.authorMartín Morquecho, Irene
dc.contributor.authorTirado Conte, Gabriela
dc.contributor.authorPérez-Vizcayno, María José
dc.contributor.authorGómez de Diego, José Juan
dc.contributor.authorArnold, Roman
dc.contributor.authorAldazábal, Andrés
dc.contributor.authorRojas, Paol
dc.contributor.authorAgustín, Alberto de
dc.contributor.authorTrigo, María Del
dc.contributor.authorGutiérrez, Hipólito
dc.contributor.authorSan Román, José A.
dc.contributor.authorMacaya Miguel, Carlos
dc.contributor.authorNombela Franco, Luis
dc.date.accessioned2026-03-02T10:38:39Z
dc.date.available2026-03-02T10:38:39Z
dc.date.issued2017-11-28
dc.description.abstractIntroduction and objectives: The SAPIEN 3 (S3) valve and the Medtronic Evolut R (EVR) are secondgeneration transcatheter valves, designed to further reduce the rate of paravalvular aortic regurgitation (AoR). The aim of this study was to compare the 2 devices in terms of valve performance in a casematched study with independent echocardiographic analysis. Methods: Of a population of 201 patients who underwent transcatheter aortic valve implantation, 144 patients (S3, n = 80; EVR, n = 64) were matched according to aortic annulus diameter and aortic valve calcium score, as assessed by computed tomography. All echocardiographic examinations collected at baseline and at 1- and 6-month follow-up were centrally analyzed. Results: The 2 groups were well balanced in baseline clinical and echocardiographic characteristics. The EVR valve showed a better hemodynamic profile as assessed by peak aortic gradient (EVR 13 7 vs S3 20 10 mmHg; P < .001), mean aortic gradient (EVR 7 3 vs S3 11 6 mmHg; P < .001), and Doppler velocity index (EVR 0.65 0.15 vs S3 0.51 0.16; P < .001). The rate of moderate-severe or any paravalvular ( mild) AoR was higher in the EVR group (11% and 50%) than in the S3 group (2.5% and 21%; P < .05, respectively), with a larger number of paravalvular jets (P < .001). Conclusions: In a case-matched cohort of transcatheter aortic valve implantation patients, the S3 valve was associatedwitha lower rate ofparavalvularAoR but alsowithahigher residual gradientthanthe EVRsystem.
dc.description.departmentDepto. de Medicina
dc.description.facultyFac. de Medicina
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationEnríquez-Rodríguez E, Amat-Santos IJ, Jiménez-Quevedo P, Martín-Morquecho I, Tirado-Conte G, Pérez-Vizcayno MJ, et al. Comparación de la hemodinámica valvular de la prótesis transcatéter con balón expandible SAPIEN 3 frente a la autoexpandible Evolut R: estudio de casos emparejados. Revista Española de Cardiología 2018;71:735–42. https://doi.org/10.1016/j.recesp.2017.10.032
dc.identifier.doi10.1016/j.rec.2017.10.025
dc.identifier.officialurlhttps://doi.org/ 10.1016/j.rec.2017.10.025
dc.identifier.relatedurlhttps://www.sciencedirect.com/science/article/abs/pii/S0300893217306310?via%3Dihub
dc.identifier.urihttps://hdl.handle.net/20.500.14352/133626
dc.issue.number9
dc.journal.titleRevista Espanola de Cardiologia
dc.language.isoeng
dc.page.final742
dc.page.initial735
dc.publisherElsevier
dc.rights.accessRightsrestricted access
dc.subject.ucmCardiología
dc.subject.unesco3205.01 Cardiología
dc.titleComparison of the Hemodynamic Performance of the Balloon-expandable SAPIEN 3 Versus Self-expandable Evolut R Transcatheter Valve: A Case-matched Study
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number71
dspace.entity.typePublication
relation.isAuthorOfPublicationb775562d-8fda-4abe-aaf2-fd622b25a3e8
relation.isAuthorOfPublication.latestForDiscoveryb775562d-8fda-4abe-aaf2-fd622b25a3e8

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Enríquez-Rodríguez (2018). Hemodinámica valvular: SAPIEN 3 vs Evolut R. Rev Esp Cardiol.pdf
Size:
424.72 KB
Format:
Adobe Portable Document Format

Collections