Comparison of the Hemodynamic Performance of the Balloon-expandable SAPIEN 3 Versus Self-expandable Evolut R Transcatheter Valve: A Case-matched Study
| dc.contributor.author | Enríquez Rodríguez, Eduardo | |
| dc.contributor.author | Amat Santos, Ignacio J. | |
| dc.contributor.author | Jiménez Quevedo, Pilar | |
| dc.contributor.author | Martín Morquecho, Irene | |
| dc.contributor.author | Tirado Conte, Gabriela | |
| dc.contributor.author | Pérez-Vizcayno, María José | |
| dc.contributor.author | Gómez de Diego, José Juan | |
| dc.contributor.author | Arnold, Roman | |
| dc.contributor.author | Aldazábal, Andrés | |
| dc.contributor.author | Rojas, Paol | |
| dc.contributor.author | Agustín, Alberto de | |
| dc.contributor.author | Trigo, María Del | |
| dc.contributor.author | Gutiérrez, Hipólito | |
| dc.contributor.author | San Román, José A. | |
| dc.contributor.author | Macaya Miguel, Carlos | |
| dc.contributor.author | Nombela Franco, Luis | |
| dc.date.accessioned | 2026-03-02T10:38:39Z | |
| dc.date.available | 2026-03-02T10:38:39Z | |
| dc.date.issued | 2017-11-28 | |
| dc.description.abstract | Introduction and objectives: The SAPIEN 3 (S3) valve and the Medtronic Evolut R (EVR) are secondgeneration transcatheter valves, designed to further reduce the rate of paravalvular aortic regurgitation (AoR). The aim of this study was to compare the 2 devices in terms of valve performance in a casematched study with independent echocardiographic analysis. Methods: Of a population of 201 patients who underwent transcatheter aortic valve implantation, 144 patients (S3, n = 80; EVR, n = 64) were matched according to aortic annulus diameter and aortic valve calcium score, as assessed by computed tomography. All echocardiographic examinations collected at baseline and at 1- and 6-month follow-up were centrally analyzed. Results: The 2 groups were well balanced in baseline clinical and echocardiographic characteristics. The EVR valve showed a better hemodynamic profile as assessed by peak aortic gradient (EVR 13 7 vs S3 20 10 mmHg; P < .001), mean aortic gradient (EVR 7 3 vs S3 11 6 mmHg; P < .001), and Doppler velocity index (EVR 0.65 0.15 vs S3 0.51 0.16; P < .001). The rate of moderate-severe or any paravalvular ( mild) AoR was higher in the EVR group (11% and 50%) than in the S3 group (2.5% and 21%; P < .05, respectively), with a larger number of paravalvular jets (P < .001). Conclusions: In a case-matched cohort of transcatheter aortic valve implantation patients, the S3 valve was associatedwitha lower rate ofparavalvularAoR but alsowithahigher residual gradientthanthe EVRsystem. | |
| dc.description.department | Depto. de Medicina | |
| dc.description.faculty | Fac. de Medicina | |
| dc.description.refereed | TRUE | |
| dc.description.status | pub | |
| dc.identifier.citation | Enríquez-Rodríguez E, Amat-Santos IJ, Jiménez-Quevedo P, Martín-Morquecho I, Tirado-Conte G, Pérez-Vizcayno MJ, et al. Comparación de la hemodinámica valvular de la prótesis transcatéter con balón expandible SAPIEN 3 frente a la autoexpandible Evolut R: estudio de casos emparejados. Revista Española de Cardiología 2018;71:735–42. https://doi.org/10.1016/j.recesp.2017.10.032 | |
| dc.identifier.doi | 10.1016/j.rec.2017.10.025 | |
| dc.identifier.officialurl | https://doi.org/ 10.1016/j.rec.2017.10.025 | |
| dc.identifier.relatedurl | https://www.sciencedirect.com/science/article/abs/pii/S0300893217306310?via%3Dihub | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14352/133626 | |
| dc.issue.number | 9 | |
| dc.journal.title | Revista Espanola de Cardiologia | |
| dc.language.iso | eng | |
| dc.page.final | 742 | |
| dc.page.initial | 735 | |
| dc.publisher | Elsevier | |
| dc.rights.accessRights | restricted access | |
| dc.subject.ucm | Cardiología | |
| dc.subject.unesco | 3205.01 Cardiología | |
| dc.title | Comparison of the Hemodynamic Performance of the Balloon-expandable SAPIEN 3 Versus Self-expandable Evolut R Transcatheter Valve: A Case-matched Study | |
| dc.type | journal article | |
| dc.type.hasVersion | VoR | |
| dc.volume.number | 71 | |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | b775562d-8fda-4abe-aaf2-fd622b25a3e8 | |
| relation.isAuthorOfPublication.latestForDiscovery | b775562d-8fda-4abe-aaf2-fd622b25a3e8 |
Download
Original bundle
1 - 1 of 1
Loading...
- Name:
- Enríquez-Rodríguez (2018). Hemodinámica valvular: SAPIEN 3 vs Evolut R. Rev Esp Cardiol.pdf
- Size:
- 424.72 KB
- Format:
- Adobe Portable Document Format