Cup-cage construct for acute fractures of the acetabulum, re-defining indications

dc.contributor.authorChana Rodríguez, Francisco
dc.contributor.authorVillanueva Martinez, Manuel
dc.contributor.authorRojo Manaute, Jose Manuel
dc.contributor.authorSanz Ruiz, Pablo
dc.contributor.authorSanz Ruiz, Pablo
dc.contributor.authorVaquero Martin, Javier
dc.contributor.authorVaquero Martín, Francisco Javier
dc.date.accessioned2025-02-01T23:23:37Z
dc.date.available2025-02-01T23:23:37Z
dc.date.issued2012-12-01
dc.description.abstractAcetabular fractures in the elderly are challenging injuries. The use of a trabecular metal acetabular cage was investigated as the treatment option in a series of elderly patients with acetabular fractures. At a 2-year follow up, 6 elderly patients were found to have mimimum pain, increased function, and increased scores using the Merle d'Aubigné and Postel system modified by Charnley. Radiographically, the areas of morsellised autograft that surrounded the cups were seen to have incorporated uniformly well, and the acetabular fractures were healed within six months after surgery. No mechanical failure, screw breakage, loosening, or migration was noticed. This novel indication of the cup–cage construction that uses revision techniques, for selected patients and fractures, to achieve an acute stable reconstruction, should be considered as an alternative reconstruction option in elderly patients presenting with acetabular fractures.
dc.description.departmentDepto. de Cirugía
dc.description.facultyFac. de Medicina
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationChana-Rodríguez, F., Villanueva-Martínez, M., Rojo-Manaute, J., Sanz-Ruíz, P., & Vaquero-Martín, J. (2012). Cup–cage construct for acute fractures of the acetabulum, re-defining indications. Injury, 43, S28-S32. https://doi.org/10.1016/S0020-1383(13)70176-1
dc.identifier.doi10.1016/S0020-1383(13)70176-1
dc.identifier.officialurlhttps://doi.org/10.1016/S0020-1383(13)70176-1
dc.identifier.relatedurlhttps://www.sciencedirect.com/science/article/pii/S0020138313701761?via%3Dihub
dc.identifier.urihttps://hdl.handle.net/20.500.14352/117536
dc.issue.number2
dc.journal.titleInjury
dc.language.isoeng
dc.page.finals32
dc.page.initials28
dc.publisherElservier
dc.rights.accessRightsrestricted access
dc.subject.keywordCup
dc.subject.keywordTrabecular metal
dc.subject.keywordTotal hip arthroplasty
dc.subject.keywordElderly
dc.subject.keywordAcetabular fracture
dc.subject.ucmSistema musculoesquelético
dc.subject.unesco3213.10 Cirugía Ortopédica
dc.titleCup-cage construct for acute fractures of the acetabulum, re-defining indications
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number43
dspace.entity.typePublication
relation.isAuthorOfPublication61cb256b-cf25-4df5-814c-39457f0027d6
relation.isAuthorOfPublication061c75db-fa4f-42b8-a1ed-56af2ec6a137
relation.isAuthorOfPublication9dafaa7f-10d7-43d6-b9d0-b8ba2ddfcd46
relation.isAuthorOfPublication.latestForDiscovery61cb256b-cf25-4df5-814c-39457f0027d6

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Cup-cage construct for acute fractures of the aetabulum, re-defiing indications.pdf
Size:
728.69 KB
Format:
Adobe Portable Document Format

Collections