Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Influence of implant connection, abutment design and screw insertion torque on implant-abutment misfit

dc.contributor.authorVélez, Jorge
dc.contributor.authorPeláez Rico, Jesús
dc.contributor.authorLópez Suárez, Carlos
dc.contributor.authorAgustín Panadero, Rubén
dc.contributor.authorTobar Arribas, Celia
dc.contributor.authorSuárez García, María Jesús
dc.date.accessioned2024-01-31T18:45:27Z
dc.date.available2024-01-31T18:45:27Z
dc.date.issued2020-07-24
dc.description.abstractBackground: An accurate fit at the implant-abutment interface is an important factor to avoid biological and mechanical complications. The aim of this study was to evaluate the marginal misfit at the implant-abutment interface on external and Morse taper connection, with straight and angulated abutments under different insertion torque loads. Materials and Methods: A total of 120 implants were used, 60 with external connection (EC) and 60 with Morse taper connection (IC). Straight (SA) (n = 60) and angulated abutments (AA) (n = 60) were randomly screwed to each connection at different torque levels (n = 10 each): 10, 20 and 30 Ncm. All specimens were subjected to thermal and cyclic loading and the misfit was measured by scanning electron microscopy. Data were analyzed with one-way ANOVA, t-test and Kruskal-Wallis test. Results: Significant differences (p < 0.001) were found between connections and abutments regardless of the torque applied. Morse taper connections with straight and angulated abutments showed the lowest misfit values (0.6 µm). Misfit values decreased as torque increased. Conclusions: The misfit was affected by the type of connection. The type of abutment did not influence the fit in the Morse taper connection. The higher the tightening torque applied the increase in the fit of the implant-abutment interface.en
dc.description.departmentDepto. de Odontología Conservadora y Prótesis
dc.description.facultyFac. de Odontología
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationVélez J, Peláez J, López-Suárez C, Agustín-Panadero R, Tobar C, Suárez MJ. Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit. J Clin Med. 2020 Jul 24;9(8):2365.
dc.identifier.doi10.3390/jcm9082365
dc.identifier.issn2077-0383
dc.identifier.officialurlhttps//doi.org/10.3390/jcm9082365
dc.identifier.relatedurlhttps://www.mdpi.com/2077-0383/9/8/2365
dc.identifier.urihttps://hdl.handle.net/20.500.14352/97388
dc.issue.number8
dc.journal.titleJournal Clinical Medicine
dc.language.isoeng
dc.page.initial2365
dc.rights.accessRightsopen access
dc.subject.cdu616.314-089.843
dc.subject.keywordExternal connection
dc.subject.keywordInternal connection
dc.subject.keywordAbutment
dc.subject.keywordImplant-abutment interface
dc.subject.keywordMisfit
dc.subject.ucmImplantes dentales
dc.subject.unesco3213.13 Ortodoncia-Estomatología
dc.titleInfluence of implant connection, abutment design and screw insertion torque on implant-abutment misfiten
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number9
dspace.entity.typePublication
relation.isAuthorOfPublication99246851-94a2-44a2-aaa7-813b0dc6f2a0
relation.isAuthorOfPublication50dc06d4-fb59-4579-89f6-b116928d866d
relation.isAuthorOfPublication2ce5448d-f74a-4522-8344-6ca5bc99b3a9
relation.isAuthorOfPublicationaf92bed3-a22f-48cd-ba53-db36d1188124
relation.isAuthorOfPublication.latestForDiscovery99246851-94a2-44a2-aaa7-813b0dc6f2a0

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Influence of implant connection, abutment design and screw insertion torque on implant-abutment misfit.pdf
Size:
1.97 MB
Format:
Adobe Portable Document Format

Collections