Electromyographic Assessment of the Efficacy of Deep Dry Needling versus the Ischemic Compression Technique in Gastrocnemius of Medium-Distance Triathletes

dc.contributor.authorBenito de Pedro, María
dc.contributor.authorCalvo Lobo, César
dc.contributor.authorLópez-López, Daniel
dc.contributor.authorBenito de Pedro, Ana Isabel
dc.contributor.authorRomero-Morales, Carlos
dc.contributor.authorSan Antolín, Marta
dc.contributor.authorVicente Campos, Davinia
dc.contributor.authorRodríguez Sanz, David
dc.date.accessioned2023-06-17T08:33:58Z
dc.date.available2023-06-17T08:33:58Z
dc.date.issued2021-04-21
dc.description.abstractSeveral studies have shown that gastrocnemius is frequently injured in triathletes. The causes of these injuries are similar to those that cause the appearance of the myofascial pain syndrome (MPS). The ischemic compression technique (ICT) and deep dry needling (DDN) are considered two of the main MPS treatment methods in latent myofascial trigger points (MTrPs). In this study superficial electromyographic (EMG) activity in lateral and medial gastrocnemius of triathletes with latent MTrPs was measured before and immediately after either DDN or ICT treatment. Taking into account superficial EMG activity of lateral and medial gastrocnemius, the immediate effectiveness in latent MTrPs of both DDN and ICT was compared. A total of 34 triathletes was randomly divided in two groups. The first and second groups (n = 17 in each group) underwent only one session of DDN and ICT, respectively. EMG measurement of gastrocnemius was assessed before and immediately after treatment. Statistically significant differences (p = 0.037) were shown for a reduction of superficial EMG measurements differences (%) of the experimental group (DDN) with respect to the intervention group (ICT) at a speed of 1 m/s immediately after both interventions, although not at speeds of 1.5 m/s or 2.5 m/s. A statistically significant linear regression prediction model was shown for EMG outcome measurement differences at V1 (speed of 1 m/s) which was only predicted for the treatment group (R2 = 0.129; β = 8.054; F = 4.734; p = 0.037) showing a reduction of this difference under DDN treatment. DDN administration requires experience and excellent anatomical knowledge. According to our findings immediately after treatment of latent MTrPs, DDN could be advisable for triathletes who train at a speed lower than 1 m/s, while ICT could be a more advisable technique than DDN for training or competitions at speeds greater than 1.5 m/s
dc.description.departmentSección Deptal. de Radiología, Rehabilitación y Fisioterapia (Enfermería)
dc.description.facultyFac. de Enfermería, Fisioterapia y Podología
dc.description.refereedTRUE
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/78514
dc.identifier.doi10.3390/s21092906
dc.identifier.issn1424-8220
dc.identifier.officialurlhttps://doi.org/10.3390/s21092906
dc.identifier.relatedurlhttps://www.mdpi.com/1424-8220/21/9/2906
dc.identifier.urihttps://hdl.handle.net/20.500.14352/7453
dc.issue.number9
dc.journal.titleSensors
dc.language.isoeng
dc.page.initial2906
dc.publisherMDPI
dc.rightsAtribución 3.0 España
dc.rights.accessRightsopen access
dc.rights.urihttps://creativecommons.org/licenses/by/3.0/es/
dc.subject.cdu796:615.83
dc.subject.keywordMyofascial pain syndrome
dc.subject.keywordTrigger points
dc.subject.keywordElectromyography
dc.subject.keywordDeep dry needling
dc.subject.keywordIschemic pressure technique
dc.subject.ucmFisioterapia (Enfermería, Fisioterapia y Podología)
dc.subject.unesco3213.11 Fisioterapia
dc.titleElectromyographic Assessment of the Efficacy of Deep Dry Needling versus the Ischemic Compression Technique in Gastrocnemius of Medium-Distance Triathletes
dc.typejournal article
dc.volume.number21
dspace.entity.typePublication
relation.isAuthorOfPublication9420a0f4-5654-4ad9-a920-e9521d454023
relation.isAuthorOfPublication3d3e5c8a-15a9-4991-97ee-ea886940b1a5
relation.isAuthorOfPublication.latestForDiscovery9420a0f4-5654-4ad9-a920-e9521d454023

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
sensors-21-02906.pdf
Size:
1.15 MB
Format:
Adobe Portable Document Format

Collections