Evaluación de la efectividad y predictibilidad de movimientos transversales con un alineador híbrido que incluye brackets virtuales y arcos de níquel titanio
| dc.contributor.advisor | Martín Álvaro, María Concepción | |
| dc.contributor.author | León Valencia, Johnny | |
| dc.date.accessioned | 2026-02-27T11:27:25Z | |
| dc.date.available | 2026-02-27T11:27:25Z | |
| dc.date.defense | 2025-04-07 | |
| dc.date.issued | 2026-02-27 | |
| dc.description | Tesis inédita de la Universidad Complutense de Madrid, Facultad de Odontología, leída el 07-04-2025 | |
| dc.description.abstract | Objetivo General: Como objetivo general, nos proponemos evaluar la efectividad y predictibilidad de los movimientos transversales obtenidos mediante el uso de un alineador híbrido (grupo GT). Adicionalmente, se plantea comparar la efectividad y predictibilidad lograda con un grupo control tratado con alineadores convencionales (grupo CA).Objetivos Específicos:1.Evaluar la efectividad y predictibilidad de los movimientos de expansión de las distancias intercaninas e interpremolares mediante el uso del alineador híbrido.2.Evaluar la efectividad y predictibilidad de los movimientos de expansión de las distancias intercaninas e interpremolares mediante el uso del alineador convencional.3.Comparar la efectividad y predictibilidad de los movimientos transversales en las distancias intercaninas e interpremolares entre el uso de alineadores híbridos y el alineador convencional. Materiales y Métodos: Este estudio clínico incluyó a 40 pacientes adultos, con 20 pacientes asignados a cada grupo de tratamiento (GT y CA). Los pacientes fueron diagnosticados con compresión dentoalveolar y apiñamiento con medidas superiores a 3 mm. Los sujetos fueron reclutados en dos clínicas odontológicas privadas en Madrid. Los cambios transversales se midieron a nivel de las cúspides y puntos cervicales para caninos, primeros premolares y segundos premolares tras la finalización del primer conjunto de alineadores. Las mediciones se realizaron utilizando archivos digitales 3D obtenidos de escaneos intraorales y analizados con el software Ortho Analyzer para garantizar la precisión y la reproducibilidad. La recolección de datos se centró en la duración del tratamiento, la cantidad de alineadores utilizados y el porcentaje de expansión lograda frente a lo planificado. Se realizaron pruebas t pareadas para comparar las mediciones planificadas y logradas dentro de cada grupo, se emplearon coeficientes de correlación de Pearson para evaluar la relación entre las expansiones planificadas y logradas en cada grupo. Para comparar los resultados entre los grupos GT y CA, se llevaron a cabo pruebas t independientes... | |
| dc.description.abstract | Objectives: As a general objective, we aim to evaluate the effectiveness and predictability of transverse movements achieved through the use of the hybrid aligner (GT group). Additionally, we propose to compare this effectiveness and predictability with that achieved in a control group treated with conventional aligners (CA group).Specific Objectives:1.To evaluate the effectiveness and predictability of expansion movements in intercanine and interpremolar distances using the hybrid aligner.2.To evaluate the effectiveness and predictability of expansion movements in intercanine and interpremolar distances using conventional aligners.3.To compare the effectiveness and predictability of transverse movements in intercanine and interpremolar distances between the hybrid aligner and conventional aligners.Materials and Methods: This clinical study included 40 adult patients, with 20 patients assigned to each treatment group (GT and CA). Patients were diagnosed with dentoalveolar constriction and crowding greater than 3 mm. Subjects were recruited from two private dental clinics in Madrid. Transverse changes were measured at the cusp tips and cervical points of the canines, first premolars, and second premolars after completing the first set of aligners. Measurements were taken using 3D digital files obtained from intraoral scans and analyzed with OrthoAnalyzer software to ensure accuracy and reproducibility. Data collection focused on treatment duration, the number of aligners used, and the percentage of expansion achieved compared to the planned outcomes. Paired t-tests were conducted to compare the planned and achieved measurements within each group, and Pearson correlation coefficients were used to evaluate the relationship between planned and achieved expansions in each group. Independent t-tests were performed to compare the results between the GT and CA groups... | |
| dc.description.faculty | Fac. de Odontología | |
| dc.description.refereed | TRUE | |
| dc.description.status | unpub | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14352/133477 | |
| dc.language.iso | spa | |
| dc.page.total | 133 | |
| dc.publication.place | Madrid | |
| dc.publisher | Universidad Complutense de Madrid | |
| dc.rights.accessRights | open access | |
| dc.subject.cdu | 616.314-089.23(043.2) | |
| dc.subject.keyword | Ortodoncia | |
| dc.subject.keyword | Orthodontics | |
| dc.subject.ucm | Ortodoncia | |
| dc.subject.unesco | 3213.13 Ortodoncia-Estomatología | |
| dc.title | Evaluación de la efectividad y predictibilidad de movimientos transversales con un alineador híbrido que incluye brackets virtuales y arcos de níquel titanio | |
| dc.type | doctoral thesis | |
| dspace.entity.type | Publication | |
| relation.isAdvisorOfPublication | 523be9a6-dc46-4774-9ef0-479abc968f7f | |
| relation.isAdvisorOfPublication.latestForDiscovery | 523be9a6-dc46-4774-9ef0-479abc968f7f |