Analysis of intra-observer´s repeatability in retinopathy´s classification of patients with, both, clear and yellow IOL´S implantation.
dc.conference.date | 2 de mayo, 2009 | |
dc.conference.place | Fort Lauderdale, Florida, Estados Unidos. | |
dc.conference.title | VIII Annual Pan-American Research Day 2009- Pre ARVO | |
dc.contributor.author | Pérez Carrasco, María Jesús | |
dc.contributor.author | Sánchez Ramos, Celia | |
dc.contributor.author | Vinas Pena, M. | |
dc.contributor.author | Bonnin Arias, Cristina Natalia | |
dc.contributor.author | Forlan, A. | |
dc.contributor.author | San Miguel, M. | |
dc.contributor.author | Ramírez, G. | |
dc.date.accessioned | 2024-10-04T14:25:03Z | |
dc.date.available | 2024-10-04T14:25:03Z | |
dc.date.issued | 2009-05-02 | |
dc.description.abstract | PURPOSE: to discriminate between different moderate retinopathies according to the clinical Age-Related Maculopathy Staging System (CARMS) using for it retinographies. Also to analyze de intra-observer`s reliability. METHODS: 808 retinographies were made to 101 subjects (both gender). Every patient had suffered cataract surgery with clear and yellow IOL´s implantation, 55 retinographies were classified by using CARMS system, which categorizes the images depending on the Drusen´s presence or absense, retinal pigment epithelium irregularities, geographic atrophy, pigment epithelium detachment and choroidal neovascularisation. The 55 retinographies categorizing was made by 2 experts in a blind, independent way. The method followed consisted in 2 different sequences with every of the 3 evaluated systems. The goal of the doubled-classification-method, with changing order no randomised, was to reject the influence of the evaluation of the previous image in the following one (Velo´s effect). Inter-observer´s repetability was checked, because of Kappa index was calculated, as an agreement parameter between both Experts. RESULTS: Intra-observer´s reliability analysis was the following: CARMS concondance obtained was 87.27% for observer A and 95.45% for the observer B. The expected concordance was 57.36% and 57044% for A and B respectively. Kappa index was 0.7016 and 008932 for A and B respectively. Drusen`s concordance obtained for observer A eas 87.27% and 98.18% for observer B. The expeted values were 59050% and 61.16% for A and B respectively. Kappa index was 0.6857 and 0.9532 for A and B respectively. Pigmentation´s concordance obteined was 87027% and 92.73%, for A and B observers. The expected concordance was 55021% and 53.72% for A and B and Kappa indexes were 0.7159 and 0.8429 for both. The reliability measured by Kappa index followed the rule: 0.80-1.00 (Excellent), 0.60-0.80 (Good), 0.40-0.60 (Moderate), 0.20-0.40 (Low), <0.20 (Bad). CONCLUSIONS: Kappa´s indexes obteined for the intra-observer analysis show a good reliability, between Godd and Excellent. A higher discrepancy in the firs retinas, which were classified, was observed. This means that a previous trainins is necessary. | |
dc.description.department | Depto. de Optometría y Visión | |
dc.description.faculty | Fac. de Óptica y Optometría | |
dc.description.refereed | TRUE | |
dc.description.status | pub | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/108654 | |
dc.language.iso | eng | |
dc.rights.accessRights | open access | |
dc.subject.cdu | 617.7 | |
dc.subject.cdu | 617.751.9 | |
dc.subject.keyword | Age-related | |
dc.subject.keyword | Macular degeneration | |
dc.subject.keyword | Imaging | |
dc.subject.keyword | Image analysis | |
dc.subject.keyword | Clinical | |
dc.subject.keyword | Drusen | |
dc.subject.ucm | Óptica y optometría | |
dc.subject.ucm | Baja visión | |
dc.subject.ucm | Oftalmología | |
dc.subject.unesco | 2209 Óptica | |
dc.subject.unesco | 2209.15 Optometría | |
dc.subject.unesco | 3201.09 Oftalmología | |
dc.title | Analysis of intra-observer´s repeatability in retinopathy´s classification of patients with, both, clear and yellow IOL´S implantation. | |
dc.title.alternative | Análisis de la repetibilidad intraobservador en la clasificación de la retinopatía de pacientes con implantación de LIO transparentes y amarillas. | |
dc.type | conference paper | |
dc.type.hasVersion | AM | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 7791e9b0-678d-49da-9010-8f913d903d58 | |
relation.isAuthorOfPublication | 3360352c-552e-4aab-aa7d-ec88baa8079e | |
relation.isAuthorOfPublication | bd1d6d70-bafd-4ab0-a203-4b33b5d9cff1 | |
relation.isAuthorOfPublication.latestForDiscovery | 7791e9b0-678d-49da-9010-8f913d903d58 |
Download
Original bundle
1 - 1 of 1
Loading...
- Name:
- Analysis_of_intraobservers_repeatability_in_retinopathys_classification.pdf
- Size:
- 247.17 KB
- Format:
- Adobe Portable Document Format