Conventional and digital complete-arch implant impression techniques: an in vitro study comparing accuracy

dc.contributor.authorGómez Polo, Miguel Ángel
dc.contributor.authorSallorenzo, Alessandro
dc.contributor.authorCascos, Rocío
dc.contributor.authorBallesteros, Juan
dc.contributor.authorBarmak, Abdul Bassir
dc.contributor.authorRevilla-León, Marta
dc.date.accessioned2024-12-18T10:07:03Z
dc.date.available2024-12-18T10:07:03Z
dc.date.issued2024-10
dc.description.abstractStatement of problem: Varying complete arch digital-implant-scanning techniques have been described, but their accuracy remains uncertain. Purpose: The purpose of this in vitro investigation was to assess the effect of the implant angulation and impression method (conventional, intraoral digital scan, intraoral scan with a splinting framework, and combining cone beam computed tomography [CBCT] and intraoral scan) on the accuracy of complete arch implant recording. Material and methods: The following 2 casts were obtained: one with 4 parallel (P group) and the other with 4 angled (up to 30 degrees) implant abutment analogs (NP group). Both the casts were digitized (7Series Scanner) (control file). The following 4 subgroups were created: conventional polyether impression with a splinted framework (CNV subgroup), intraoral scan (IOS subgroup), intraoral scan with a splinting framework (S-IOS subgroup), and intraoral scan combined with CBCT scan (CBCT-IOS subgroup) (n=10). For each file, an implant-supported bar was designed and imported into a program (Netfabb) to perform linear and angular interimplant abutment measurements. Two-way ANOVA (Analysis of Variance) and Tukey tests were selected to examine the data (α=.05). Results: Implant angulation (P=.010) and impression method (P=.003) significantly influenced the linear trueness. The P group (112 μm) obtained better linear trueness than the NP group (144 μm). The CNV subgroup obtained the best linear trueness, while the IOS and CBCT-IOS showed the worst trueness. Group (P<.001) significantly influenced angular trueness. Group (P=.009) and subgroup (P<.001) influenced the linear precision. The P group (72 μm) obtained better linear precision than the NP group (91 μm). The IOS subgroup obtained the best linear precision. Group (P=.034) significantly influenced the angular precision. The P group (0.46 degrees) had higher angular precision compared with the NP group (0.60 degrees). Conclusions: Implant angulation and the impression methods tested, impacted the accuracy of the complete arch implant recording. Parallel implants had better trueness and precision values than nonparallel implants. The conventional impression method showed the best trueness and precision. Among the digital implant scan methods assessed, the S-IOS and CBCT-IOS subgroups acquired significantly better trueness and precision than the IOS subgroup.
dc.description.departmentDepto. de Odontología Conservadora y Prótesis
dc.description.facultyFac. de Odontología
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationGómez-Polo M, Sallorenzo A, Cascos R, Ballesteros J, Barmak AB, Revilla-León M. Conventional and digital complete arch implant impression techniques: An in vitro study comparing accuracy. J Prosthet Dent. 2024 Oct;132(4):809-818. doi: 10.1016/j.prosdent.2022.08.028
dc.identifier.doi10.1016/j.prosdent.2022.08.028
dc.identifier.essn1097-6841
dc.identifier.issn0022-3913
dc.identifier.officialurlhttps://doi.org/10.1016/j.prosdent.2022.08.028
dc.identifier.pmid36539313
dc.identifier.relatedurlhttps://www.sciencedirect.com/science/article/pii/S0022391322005558?via%3Dihub
dc.identifier.relatedurlhttps://pubmed.ncbi.nlm.nih.gov/36539313/
dc.identifier.urihttps://hdl.handle.net/20.500.14352/112877
dc.issue.number4
dc.journal.titleThe Journal of Prosthetic Dentistry
dc.language.isoeng
dc.page.final818
dc.page.initial809
dc.publisherElsevier
dc.rights.accessRightsembargoed access
dc.subject.cdu616-073
dc.subject.cdu616.314-089.843
dc.subject.keywordProsthodontics
dc.subject.keywordDental Implants
dc.subject.keywordDental Impression Technique*
dc.subject.keywordDental Impression Materials
dc.subject.ucmOdontología (Odontología)
dc.subject.ucmDiagnóstico por imagen y medicina nuclear
dc.subject.ucmImplantes dentales
dc.subject.unesco3213.13 Ortodoncia-Estomatología
dc.subject.unesco2209.90 Tratamiento Digital. Imágenes
dc.titleConventional and digital complete-arch implant impression techniques: an in vitro study comparing accuracy
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number132
dspace.entity.typePublication
relation.isAuthorOfPublication9700c70b-34f2-4d6a-8e12-92587c9186fb
relation.isAuthorOfPublication.latestForDiscovery9700c70b-34f2-4d6a-8e12-92587c9186fb

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
J Prosthet Dent. 2024 Oct;132(4):809-818 .pdf
Size:
971.89 KB
Format:
Adobe Portable Document Format

Collections