Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Accommodative changes produced in response to overnight orthokeratology

dc.contributor.authorFelipe Márquez, Gema
dc.contributor.authorNombela Palomo, María
dc.contributor.authorCacho, Isabel
dc.contributor.authorNieto Bona, Amelia
dc.date.accessioned2023-06-18T05:41:42Z
dc.date.available2023-06-18T05:41:42Z
dc.date.issued2015-04
dc.description.abstractBackground To evaluate short-term (3 months) and long-term (3 years) accommodative changes produced by overnight orthokeratology (OK). Methods A prospective, longitudinal study on young adult subjects with low to moderate myopia was carried out. A total of 93 patients took part in the study. Out of these, 72 were enrolled into the short-term follow-up: 21 were on a control group, 26 on a Paragon CRT contact lenses group, and 25 on a Seefree contact lenses group. The other 21 patients were old CRT wearers on long-term follow-up. Accommodative function was assessed by means of negative and positive relative accommodation (NRA / PRA), monocular accommodative amplitude (MAA), accommodative lag, and monocular accommodative facility (MAF). These values were compared among the three short-term groups at the follow-up visit. The long- and short-term follow-up data was compared among the CRT groups. Results Subjective accommodative results did not suffer any statistically significant changes in any of the accommodative tests for any of the short-term groups when compared to baseline. There were no statistically significant differences between the three short-term groups at the follow-up visit. When comparing the short- and long-term groups, only the NRA showed a significant difference (p = 0.0006) among all the accommodation tests. Conclusions OK does not induce changes in the ocular accommodative function for either short-term or long-term periods.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/40651
dc.identifier.doi10.1007/s00417-014-2865-2
dc.identifier.issn0721-832X
dc.identifier.officialurlhttp://dx.doi.org/10.1007/s00417-014-2865-2
dc.identifier.urihttps://hdl.handle.net/20.500.14352/23067
dc.issue.number4
dc.journal.titleGraefe's Archive for Clinical and Experimental Ophthalmology
dc.language.isoeng
dc.page.final626
dc.page.initial619
dc.publisherSpringer
dc.rights.accessRightsrestricted access
dc.subject.cdu617.7-001.15
dc.subject.cdu617.713-089
dc.subject.keywordOrthokeratology
dc.subject.keywordAccommodative function
dc.subject.keywordAccommodative amplitude
dc.subject.keywordMyopia
dc.subject.keywordContact lenses
dc.subject.ucmOftalmología
dc.subject.ucmOptometría
dc.subject.unesco3201.09 Oftalmología
dc.subject.unesco2209.15 Optometría
dc.titleAccommodative changes produced in response to overnight orthokeratology
dc.typejournal article
dc.volume.number253
dcterms.references1. Alpern M (1949) Accommodation and convergence with contact lenses. Am J Optom Arch Am Acad Optom 26:379–387 2. Robertson DM, Ogle KN, Dyer JA (1967) Influence of contact lenses on accommodation. Theoretic considerations and clinical study. Am J Ophthalmol 64:860–871 3. Carney LG, Woo GC (1977) Comparison of accommodation with rigid and flexible contact lenses. Am J Optom Physiol Optic 54:595–597 4. Jimenez R, Martinez-Almeida L, Salas C, Ortiz C (2011) Contact lenses vs spectacles in myopes: is there any difference in accommodative and binocular function? Graefes Arch Clin Exp Ophthalmol 249:925–935. doi:10.1007/s00417-010-1570-z 5. Liu L, Yuan J, Li J, Li X, Wang Y (2008) Effect of laser in situ keratomileusis on accommodation. J Huazhong Univ Sci Technol Med Sci 28:596–598. doi:10.1007/s11596-008-0524-8 6. Karimian F, Baradaran-Rafii A, Bagheri A, Eslani M, Bayat H, Aramesh S, Yaseri M, Amin-Shokravi A (2010) Accommodative changes after photorefractive keratectomy in myopic eyes. Optom Vis Sci 87:833–838. doi:10.1097/OPX.0b013e3181f6fccc 7. Koffler BH, Sears JJ (2013) Myopia control in children through refractive therapy gas permeable contact lenses: is it for real? Am J Ophthalmol 156(6):1076.e1–1081.e1. doi:10.1016/j.ajo.2013.04.039 8. Cheung SW, Cho P (2013) Validity of axial length measurements for monitoring myopic progression in orthokeratology. Invest Ophthalmol Vis Sci 54:1613–1615. doi:10.1167/iovs. 12-10434 9. Cho P, Cheung SW (2012) Retardation of myopia in Orthokeratology (ROMIO) study: a 2-year randomized clinical trial. Invest Ophthalmol Vis Sci 53:7077–7085. doi:10.1167/iovs. 12-10565 10. Santodomingo-Rubido J, Villa-Collar C, Gilmartin B, Gutierrez-Ortega R (2012) Myopia control with orthokeratology contact lenses in Spain: refractive and biometric changes. Invest Ophthalmol Vis Sci 53:5060–5065. doi:10.1167/iovs. 11-8005 11. Hiraoka T, Kakita T, Okamoto F, Takahashi H, Oshika T (2012) Long-term effect of overnight orthokeratology on axial length elongation in childhood myopia: a 5-year follow-up study. Invest Ophthalmol Vis Sci 53:3913–3919. doi:10.1167/iovs. 11-8453 12. Kakita T, Hiraoka T, Oshika T (2011) Influence of overnight orthokeratology on axial elongation in childhood myopia. Invest Ophthalmol Vis Sci 52:2170–2174. doi:10.1167/iovs. 10-5485 13. Walline JJ, Jones LA, Sinnott LT (2009) Corneal reshaping and myopia progression. Br J Ophthalmol 93:1181–1185. doi:10.1136/bjo.2008.151365 14. Cho P, Cheung SW, Edwards M (2005) The longitudinal orthokeratology research in children (LORIC) in Hong Kong: a pilot study on refractive changes and myopic control. Curr Eye Res 30:71–80. doi:10.1080/02713680590907256 15. McLeod ADL (2006) Effects of overnight orthokeratology on phoria, vergence, and accommodation in children. New England College of Optometry, pp. xi, 125 p 16. Brand P (2013) The effect of orthokeratology on accommodative and convergence function: a clinic based pilot study. Optom Vis Perform 1:162–167 17. Antona Peñalba B (2010) Fiabilidad intraexaminador y concordancia de pruebas clínicas de evaluación de la visión binocular Optica II (Optometría y visión). Universidad Complutense de Madrid, Madrid. Spain, pp. 251. Thesis. http://eprints.ucm.es/10149/1/T30728.pdf 18. Antona B, Barra F, Barrio A, Gonzalez E, Sanchez I (2009) Repeatability intraexaminer and agreement in amplitude of accommodation measurements. Graefes Arch Clin Exp Ophthalmol 247:121–127. doi:10.1007/s00417-008-0938-9 19. Nieto-Bona A, Gonzalez-Mesa A, Nieto-Bona MP, Villa-Collar C, Lorente-Velazquez A (2011) Short-term effects of overnight orthokeratology on corneal cell morphology and corneal thickness. Cornea 30:646–654. doi:10.1097/ICO.0b013e31820009bc 20. Nieto-Bona A, Gonzalez-Mesa A, Nieto-Bona MP, Villa-Collar C, Lorente-Velazquez A (2011) Long-term changes in corneal morphology induced by overnight orthokeratology. Curr Eye Res 36:895–904. doi:10.3109/02713683.2011.593723 21. Palomo-Alvarez C, Puell MC (2008) Accommodative function in school children with reading difficulties. Graefes Arch Clin Exp Ophthalmol 246:1769–1774. doi:10.1007/s00417-008-0921-5 22. Scheiman MM, Wick B (2008) Clinical management of binocular vision : heterophoric, accommodative and eye movement disorders. Lippincott Williams & Wilkins, Philadelphia 23. Santodomingo-Rubido J, Villa-Collar C, Gilmartin B, Gutierrez-Ortega R (2014) Short-term changes in ocular biometry and refraction after discontinuation of long-term orthokeratology. Eye Contact Lens 40:84–90. doi:10.1097/icl.0000000000000014 24. Santolaria E, Cervino A, Queiros A, Brautaset R, Gonzalez-Meijome JM (2013) Subjective satisfaction in long-term orthokeratology patients. Eye Contact Lens 39:388–393. doi:10.1097/ICL.0b013e3182a27777 25. Swarbrick HA (2006) Orthokeratology review and update. Clin Exp Optom 89:124–143. doi:10.1111/j.1444-0938.2006.00044.x 26. Cacho-Martinez P, Garcia-Munoz A, Ruiz-Cantero MT (2014) Is there any evidence for the validity of diagnostic criteria used for accommodative and nonstrabismic binocular dysfunctions? J Optom 7:2–21. doi:10.1016/j.optom.2013.01.004 27. Ninomiya S, Fujikado T, Kuroda T, Maeda N, Tano Y, Oshika T, Hirohara Y, Mihashi T (2002) Changes of ocular aberration with accommodation. Am J Ophthalmol 134:924–926 28. Hazel CA, Cox MJ, Strang NC (2003) Wavefront aberration and its relationship to the accommodative stimulus–response function in myopic subjects. Optom Vis Sci 80:151–158 29. Cheng H, Barnett JK, Vilupuru AS, Marsack JD, Kasthurirangan S, Applegate RA, Roorda A (2004) A population study on changes in wave aberrations with accommodation. J Vis 4:272–280. doi:10.1167/4.4.3 30. Iida Y, Shimizu K, Ito M, Suzuki M (2008) Influence of age on ocular wavefront aberration changes with accommodation. J Refract Surg 24:696–701 31. Yuan Y, Shao Y, Tao A, Shen M, Wang J, Shi G, Chen Q, Zhu D, Lian Y, Qu J, Zhang Y, Lu F (2013) Ocular anterior segment biometry and high-order wavefront aberrations during accommodation. Invest Ophthalmol Vis Sci 54:7028–7037. doi:10.1167/iovs. 13-11893 32. Hiraoka T, Miyata K, Nakamura Y, Ogata M, Okamoto F, Oshika T (2014) Influence of cycloplegia with topical cyclopentolate on higher-order aberrations in myopic children. Eye (Lond). doi:10.1038/eye.2014.34 33. Tarrant J, Liu Y, Wildsoet CF (2009) Orthokeratology can decrease the accommodative lag in myopes. ARVO Meet Abstr 50:4294 34. Gifford P, Li M, Lu H, Miu J, Panjaya M, Swarbrick HA (2013) Corneal versus ocular aberrations after overnight orthokeratology. Optom Vis Sci 90:439–447. doi:10.1097/OPX.0b013e31828ec594 35. Gonzalez-Mesa A, Villa-Collar C, Lorente-Velazquez A, Nieto-Bona A (2013) Anterior segment changes produced in response to long-term overnight orthokeratology. Curr Eye Res 38:862–870. doi:10.3109/02713683.2013.790977 36. Owens H, Garner LF, Craig JP, Gamble G (2004) Posterior corneal changes with orthokeratology. Optom Vis Sci 81:421–426 37. Stillitano IG, Chalita MR, Schor P, Maidana E, Lui MM, Lipener C, Hofling-Lima AL (2007) Corneal changes and wavefront analysis after orthokeratology fitting test. Am J Ophthalmol 144:378–386. doi:10.1016/j.ajo.2007.05.030 38. Tsukiyama J, Miyamoto Y, Higaki S, Fukuda M, Shimomura Y (2008) Changes in the anterior and posterior radii of the corneal curvature and anterior chamber depth by orthokeratology. Eye Contact Lens 34:17–20. doi:10.1097/ICL.0b013e3180515299 39. Chen D, Lam AK, Cho P (2010) Posterior corneal curvature change and recovery after 6 months of overnight orthokeratology treatment. Ophthalmic Physiol Opt 30:274–280. doi:10.1111/j.1475-1313.2010.00710.x 40. Queiros A, Villa-Collar C, Gutierrez AR, Jorge J, Ribeiro-Queiros MS, Peixoto-de-Matos SC, Gonzalez-Meijome JM (2011) Anterior and posterior corneal elevation after orthokeratology and standard and customized LASIK surgery. Eye Contact Lens 37:354–358. doi:10.1097/ICL.0b013e318232e32d 41. Yoon JH, Swarbrick HA (2013) Posterior corneal shape changes in myopic overnight orthokeratology. Optom Vis Sci 90:196–204. doi:10.1097/OPX.0b013e31828121eb 42. Yuan Y, Chen F, Shen M, Lu F, Wang J (2012) Repeated measurements of the anterior segment during accommodation using long scan depth optical coherence tomography. Eye Contact Lens 38:102–108. doi:10.1097/ICL.0b013e318243e795 43. Zhu D, Shao Y, Leng L, Xu Z, Wang J, Lu F, Shen M (2014) Automatic biometry of the anterior segment during accommodation imaged by optical coherence tomography. Eye Contact Lens. doi:10.1097/ICL.0000000000000043 44. García A, Cacho P, Lara F (2002) Evaluating relative accommodations in general binocular dysfunctions. Optom Vis Sci 79:779–787 45. Aldaba M, Vilaseca M, Arjona M, Pujol J (2013) Age-related changes in accommodation measured with a double-pass system. Ophthalmic Physiol Opt 33:508–515. doi:10.1111/opo.12038
dspace.entity.typePublication
relation.isAuthorOfPublication4f70cc93-25f2-422b-b0e9-8641febc03cb
relation.isAuthorOfPublication.latestForDiscovery4f70cc93-25f2-422b-b0e9-8641febc03cb

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
accomadative_Graefes-2015.pdf
Size:
205.16 KB
Format:
Adobe Portable Document Format

Collections