Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Nuevas tecnologías para la evaluación objetiva y la asistencia de pacientes con temblor esencial

dc.contributor.advisorSánchez Ferro, Álvaro
dc.contributor.advisorHernández Gallego, Jesús
dc.contributor.advisorBenito León, Julián
dc.contributor.authorLópez Blanco, Roberto
dc.date.accessioned2023-06-16T15:02:09Z
dc.date.available2023-06-16T15:02:09Z
dc.date.defense2020-11-04
dc.date.issued2021-07-23
dc.descriptionTesis inédita de la Universidad Complutense de Madrid, Facultad de Medicina, Departamento de Medicina, leída el 04/11/2020. Tesis formato europeo (compendio de artículos)
dc.description.abstractLas nuevas tecnologías para la medición objetiva y precisa delos trastornos del movimiento, en general, y, del temblor esencial (TE) en particular, están revolucionando el manejo de estas enfermedades. Los principales campos tecnológicos emergentes en esta área son dos. El primero está representado por los dispositivos portátiles o wearables que utilizan sistemas de medida inercial (IMUs, de su acrónimo en inglés). Los IMUs integran acelerómetros y giróscopos que proporcionan medidas de aceleración lineal y angular, respectivamente, de las diferentes partes del cuerpo donde se colocan y sirven sobre todo para monitorizar o diagnosticar. El segundo aspecto tecnológico emergente son las aplicaciones y dispositivos diseñados ad hoc que pretenden facilitar la interacción con dispositivos electrónicos de los pacientes con temblor así como controlar físicamente el temblor. Sus utilidades van desdela monitorización o el registro objetivo de temblor, hasta la asistencia de los pacientes con TE a la hora de interactuar con pantallas, e incluso terapéuticas, contrarrestando mecánicamente el temblor...
dc.description.abstractNew technologies for the objective measurement of movement disorders, particularly for essential tremor (ET), are disrupting the clinical management of these conditions. The main emerging fields are two. The first relates to wearable devices with embedded inertial measurement units (IMUs).These IMUs are composed by accelerometers and gyroscopes that register linear and angular accelerations, respectively, from the different body partsw here they are placed to monitor and diagnose a disease. The second field attains to the development of ad hoc applications and devices designed to helptremor patient access and interact with electronic devices as well as controlling physically tremor. These applications span from the continuous objective recording of tremor, to the assistance of ET patients to interact with touchscreen devices, and even the mechanical reduction of tremor...
dc.description.facultyFac. de Medicina
dc.description.refereedTRUE
dc.description.statusunpub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/67186
dc.identifier.urihttps://hdl.handle.net/20.500.14352/5565
dc.language.isospa
dc.page.total170
dc.publication.placeMadrid
dc.publisherUniversidad Complutense de Madrid
dc.rights.accessRightsopen access
dc.subject.cdu616.8-009.3(043.2)
dc.subject.keywordtemblor esencial
dc.subject.keywordessential tremor
dc.subject.ucmMedicina
dc.subject.unesco32 Ciencias Médicas
dc.titleNuevas tecnologías para la evaluación objetiva y la asistencia de pacientes con temblor esencial
dc.typedoctoral thesis
dspace.entity.typePublication
relation.isAdvisorOfPublicationfd9aa3b0-95fa-4eed-a75c-a34d5e43753c
relation.isAdvisorOfPublicationa1c7932c-7b3b-49b4-85f4-99cf7fbbb615
relation.isAdvisorOfPublication.latestForDiscoveryfd9aa3b0-95fa-4eed-a75c-a34d5e43753c

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
T42628.pdf
Size:
15.55 MB
Format:
Adobe Portable Document Format

Collections