Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Evaluation of tear meniscus by optical coherence tomography after different sodium hyaluronate eyedrops instillation

dc.contributor.authorCarracedo Rodríguez, Juan Gonzalo
dc.contributor.authorPastrana Robles, Cristina
dc.contributor.authorSerramito Blanco, María
dc.contributor.authorRodríguez-Pomar, Candela
dc.dateVersion of Record online: 02 October 2018; Manuscript accepted: 16 July 2018; Manuscript received: 30 September 2017
dc.date.accessioned2023-06-17T13:18:31Z
dc.date.available2023-06-17T13:18:31Z
dc.date.issued2018-10-02
dc.description.abstractPurpose: To evaluate changes in tear meniscus dynamics using optical coherence tomography (OCT) after the instillation of different concentrations of sodium hyaluronate (SH) ophthalmic solutions. Methods: An experimental, double‐masked, randomized study was performed. Twenty‐three healthy subjects (16 women and seven men; mean age 23.57 ± 2.56 years) participated in this study. About 35 μl of 0.1%, 0.2%, 0.3% SH ophthalmic solutions and saline solution was instilled in a randomly assigned eye. Tear meniscus measurements (height, depth and turbidity) were taken with OCT at 30 seconds and 1, 3, 5, 10 and 20 min after instillation. Subsequently, the Schirmer test and tear break‐up time (TBUT) were evaluated. Results: Tear meniscus depth and tear meniscus height showed a significant increase with all solutions compared to basal values: up to 3 min for 0.1% SH, up to 5 min for 0.2% and up to 10 min for 0.3% SH ophthalmic solution. Tear meniscus turbidity was also increased at 30 seconds for 0.1%, 0.2% and 0.3% SH artificial tears (p < 0.05). This increase remained significant for up to 1 min for 0.2% and 0.3% SH solutions (p < 0.05). After 5 min of saline and 0.1% SH instillation, the turbidity was lower than basal values (p < 0.05). There was a significant increase in the TBUT for all solutions after instillation (p < 0.05). No differences between the Schirmer pre‐ and postinstillation were found (p > 0.05). Finally, the comfort was significantly improved for all ophthalmic solutions (p < 0.05). Conclusion: Sodium hyaluronate (SH) ophthalmic solutions increase residence time in healthy subjects and are positively correlated with its concentration and therefore the viscosity.en
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.sponsorshipMinisterio de Ciencia, Innovación y Universidades (España)
dc.description.sponsorshipRedes Telemáticas de Investigación Cooperativa en Salud (España)
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/50564
dc.identifier.citationCarracedo Rodríguez, G., Pastrana Robles, C., Serramito Blanco, M., Rodríguez Pomar, C. «Evaluation of Tear Meniscus by Optical Coherence Tomography after Different Sodium Hyaluronate Eyedrops Instillation». Acta Ophthalmologica, vol. 97, n.o 2, marzo de 2019. DOI.org (Crossref), https://doi.org/10.1111/aos.13887.
dc.identifier.doi10.1111/aos.13887
dc.identifier.issn1755-375X
dc.identifier.officialurlhttps://doi.org/10.1111/aos.13887
dc.identifier.relatedurlhttps://onlinelibrary.wiley.com/doi/10.1111/aos.13887
dc.identifier.urihttps://hdl.handle.net/20.500.14352/12963
dc.journal.titleActa Ophthalmologica
dc.language.isoeng
dc.page.initial8 p.
dc.publisherWiley
dc.relation.projectID(SAF2010‐16024; SAF2013‐44416‐R)
dc.relation.projectIDRD12/0034/0003
dc.rights.accessRightsrestricted access
dc.subject.cdu615.457
dc.subject.cdu617.764
dc.subject.cdu611.846
dc.subject.keywordOptical Coherence Tomography
dc.subject.keywordSodium hyaluronate
dc.subject.keywordTear meniscus
dc.subject.keywordViscosity
dc.subject.ucmOftalmología
dc.subject.ucmAnatomía ocular
dc.subject.ucmTécnicas de la imagen
dc.subject.unesco3201.09 Oftalmología
dc.titleEvaluation of tear meniscus by optical coherence tomography after different sodium hyaluronate eyedrops instillationen
dc.typejournal article
dspace.entity.typePublication
relation.isAuthorOfPublication97433353-d31b-4cf5-b2c0-47d2e6703fe5
relation.isAuthorOfPublication02a080c4-e7d5-4c6a-9b3c-0c5bb61c00bf
relation.isAuthorOfPublication1ed070b9-44c7-486f-8475-407fbccbd9b7
relation.isAuthorOfPublication.latestForDiscovery97433353-d31b-4cf5-b2c0-47d2e6703fe5

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Carracedo_et_al-2018-Acta_Ophthalmologica.pdf
Size:
884.6 KB
Format:
Adobe Portable Document Format

Collections