Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Intrasession repeatability and agreement of the anterior corneal assessment provided by a multidiagnostic device

dc.contributor.authorBarrio De Santos, Ana Rosa
dc.contributor.authorAntona Peñalba, Beatriz
dc.contributor.authorMorago Villanueva, Sofía
dc.contributor.authorMartínez Arribas, Víctor
dc.contributor.authorGonzález Pérez, Mariano
dc.date.accessioned2024-05-24T18:14:06Z
dc.date.available2024-05-24T18:14:06Z
dc.date.issued2024-03-17
dc.descriptionReceived 07 Oct 2023, Accepted 23 Feb 2024, Published online: 17 Mar 2024
dc.description.abstractClinical relevance: Multidiagnostic systems have recently appeared on the market. Knowledge of the repeatability and validity of any instrument is mandatory before its introduction in clinical practice. Background: The aim of this work is to examine the intrasession repeatability of anterior pole measurements provided by the multidiagnostic device Wave Analyzer Medica 700 (WAM700) and agreement with Pentacam measurements in normal eyes. Methods: In the right eyes of 113 participants, three repeat measurements of central keratometry, central corneal thickness, anterior chamber depth and corneal eccentricity were made with the WAM700 and Pentacam in random order. Intrasession repeatability and agreement were determined. Results: Employing WAM700, intrasession repeatability for keratometry, central corneal thickness and anterior chamber depth was good (ICCs ≥ 0.992; CV 0.48-0.98%), yet worse than the values obtained for the Pentacam (ICCs ≥ 0.998; CV 0-0.33%). WAM700 showed excellent intrasession repeatability when used to measure the anterior chamber depth (Sw 0.03 mm). However, the repeatability of this device was inferior for central corneal thickness (Sw 4.24 μm) and keratometry measurements (Sw < 0.21 D) and was poor for corneal eccentricity (Sw 0.07; ICC 0.908; CV 14.58%). Agreement between WAM700 and Pentacam showed a high ICC for the keratometry measurements, central corneal thickness and anterior chamber depth (>0.972) but lower for corneal eccentricity (ICC 0.762). Conclusions: In healthy eyes, the WAM700 multidiagnostic device showed good intrasession repeatability for keratometry, central corneal thickness and anterior chamber depth measurements. Agreement between WAM700 and Pentacam was good for the anterior chamber depth measurement. However, these instruments cannot be considered interchangeable for keratometry, central corneal thickness and eccentricity readings.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.fundingtypePagado por el autor
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationBarrio AR, Antona B, Morago-Villanueva S, Martínez-Arribas V, González-Pérez M. Intrasession repeatability and agreement of the anterior corneal assessment provided by a multidiagnostic device. Clin Exp Optom. 2024 Mar 17:1-7. doi: 10.1080/08164622.2024.2324978. Epub ahead of print. PMID: 38494447.
dc.identifier.doi10.1080/08164622.2024.2324978
dc.identifier.essn1444-0938
dc.identifier.issn0816-4622
dc.identifier.officialurlhttps://doi.org/10.1080/08164622.2024.2324978
dc.identifier.pmid38494447
dc.identifier.relatedurlhttps://www.tandfonline.com/doi/full/10.1080/08164622.2024.2324978
dc.identifier.urihttps://hdl.handle.net/20.500.14352/104437
dc.journal.titleClinical and Experimental Optometry
dc.language.isoeng
dc.page.final7
dc.page.initial1
dc.publisherTaylor & Francis
dc.rights.accessRightsrestricted access
dc.subject.cdu617.7-073
dc.subject.cdu611.84
dc.subject.keywordAgreement
dc.subject.keywordWave Analyzer Medica 700
dc.subject.keywordAnterior segment
dc.subject.keywordCornea
dc.subject.keywordRepeatability
dc.subject.ucmÓptica y optometría
dc.subject.ucmÓptica geométrica e instrumental
dc.subject.unesco2209 Óptica
dc.subject.unesco3314 Tecnología Médica
dc.subject.unesco2410.02 Anatomía Humana
dc.titleIntrasession repeatability and agreement of the anterior corneal assessment provided by a multidiagnostic device
dc.typejournal article
dc.type.hasVersionVoR
dspace.entity.typePublication
relation.isAuthorOfPublication489b4330-7884-43a8-846f-7a6dea5cdeec
relation.isAuthorOfPublication4d93581c-fa46-4362-886f-96b13e817c13
relation.isAuthorOfPublicationca5eda64-f98e-4d56-b225-70cac495f2ea
relation.isAuthorOfPublication.latestForDiscovery489b4330-7884-43a8-846f-7a6dea5cdeec

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Intrasession_repeatability_multidiagnostic_device_2024.pdf
Size:
1.07 MB
Format:
Adobe Portable Document Format
Description:
Versión publicada en la web del editor.

Collections