dc.date.issued2023-09-12
dc.description.abstractINTRODUCTION: Currently, patients have an increased demand and high expectations for good visual quality and spectacle independence after surgery. In addition, said surgery is being performed earlier and earlier due to the visual demands that require good vision at all distances. Especially, in intermediate distances due to the appearance of new technologies and the continuous work on screens. For this reason, there is a continuous evolution of IOL designs. PURPOSE: To analyze the effect of PhysiOL ®IsoPure123™ and AcrySof ®IQ Vivity™ extended range intraocular lens design on patients visual quality under photopic and mesopic illumination conditions. Setting: The study was performed at the Hospital Universitario Sanitas la Moraleja in Madrid. All surgeries were performed by the same experienced surgeon (E.D.R). The study followed the principles of the Declaration of Helsinki. CONCLUSION: Both AcrySof ®IQ Vivity™ and PhysiOL ®IsoPure 123™ intraocular lens designs provide optimal VA for far and near distances in both photopic and mesopic illumination conditions. The AcrySof ® IQ Vivity™ IOL provides better intermediate VA under mesopic conditions than the PhysiOL ® IsoPure 123™ IOL, with this difference being clinically significant. There was no statistically significant difference between the two intraocular lenses in relation to the perception of halos.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.statusunpub
dc.identifier.relatedurlhttps://www.escrs.org/escrs-annual-events/41st-congress-of-the-escrs/
dc.identifier.urihttps://hdl.handle.net/20.500.14352/105987
dc.language.isoeng
dc.rights.accessRightsopen access
dc.subject.cdu617.7-089.243
dc.subject.cdu681.7.066
dc.subject.cdu681.73
dc.subject.cdu617.75
dc.subject.keywordIOL
dc.subject.keywordVisual quality
dc.subject.keywordDifferent illumination conditions
dc.subject.ucmÓptica y optometría
dc.subject.ucmÓptica fisiológica
dc.subject.ucmÓptica oftálmica
dc.subject.ucmCirugía
dc.subject.unesco2209.15 Optometría
dc.subject.unesco2411.15 Fisiología de la Visión
dc.subject.unesco3311.09 Lentes
dc.subject.unesco3201.09 Oftalmología
dc.titleAnalysis Of The Effects Of Two Extended-Depth- Of -Focus Intraocular Lenses On Visual Quality Under Different Illumination Conditions.
dc.title.alternativeAnálisis de los efectos de dos lentes intraoculares de profundidad de campo ampliada sobre la calidad visual en diferentes condiciones de iluminación.
dc.typeconference poster
dc.type.hasVersionVoR
dspace.entity.typePublication
relation.isAuthorOfPublicationb7f0bd69-3ee7-4f85-9053-89850d60238f
relation.isAuthorOfPublicationbd1d6d70-bafd-4ab0-a203-4b33b5d9cff1
relation.isAuthorOfPublication3360352c-552e-4aab-aa7d-ec88baa8079e
relation.isAuthorOfPublication.latestForDiscoveryb7f0bd69-3ee7-4f85-9053-89850d60238f

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ESCRS_2023_Extended_Phocus_IOL.pdf
Size:
569.87 KB
Format:
Adobe Portable Document Format
Description:
Póster de conferencia