A clinical study assessing the influence of anodized titanium and zirconium dioxide abutments and peri-implant soft tissue thickness on the optical outcome of implant-supported lithium disilicate single crowns

dc.contributor.authorMartínez Rus, Francisco
dc.contributor.authorPrieto, Marta
dc.contributor.authorSalido Rodríguez-Manzaneque, María Paz
dc.contributor.authorMadrigal Martínez-Pereda, Cristina María
dc.contributor.authorÖzcan, Mutlu
dc.contributor.authorPradíes Ramiro, Guillermo Jesús
dc.date.accessioned2025-01-22T11:53:44Z
dc.date.available2025-01-22T11:53:44Z
dc.date.issued2017-01
dc.description.abstractPurpose: To assess the influence of anodized titanium and zirconium dioxide abutments and peri-implant soft tissue thickness on the optical outcome of implant-supported lithium disilicate single crowns. Materials and methods: Twenty patients with a missing maxillary single incisor, canine, or first premolar received an endosseous implant after a two-stage surgery protocol. After healing and soft tissue conditioning, peri-implant soft tissues were reproduced in the impression, and the thickness was measured. Customized abutments were made of titanium, gold-anodized titanium, pink-anodized titanium, and zirconium dioxide. The definitive prosthesis was a lithium disilicate crown stratified by feldsphatic porcelain. Customized abutments were screwed (35 Ncm), and the crown was temporarily placed on the abutment with a try-in paste. Color measurements were made using a spectrophotometer. CIELab color scale was employed following the formula: ΔE = (ΔL)² + (Δa) ² + (Δb) ². Data were analyzed using repeated-measures analysis of variance (ANOVA), Bonferroni and Pearson's correlation tests (α = .05). Results: Abutment material type significantly affected the ΔE values at both the peri-implant soft tissue (P = .0001) and coronal level (P = .001). The lowest ΔE values were obtained with zirconia abutments at both soft tissue (6.06 ± 3.2) and coronal level (5.76 ± 2.9) compared with those of other abutments (soft tissue: 8.96 ± 3.1 to 11.56 ± 3.4; coronal: 8.66 ± 6.1 to 10.42 ± 6.3). Mean soft tissue thickness (1.63 ± 0.64 mm) affected the ΔE values at the peri-implant soft tissue level for only titanium and pink-anodized titanium abutments (P = .024 and P = .048, respectively). In all conditions, correlation coefficients between ΔE and the abutment materials were higher for titanium (r = -0.544; P = .024) and the least for zirconia (r = -0.313; P = .238) and gold-anodized titanium (r = -0.393; P = .119) abutments. Conclusion: All abutment types demonstrated noticeable color difference at both the soft tissue and coronal levels. Zirconia abutments showed the lowest ΔE values at both measurement zones. Soft tissue thickness did not affect the ΔE values at the peri-implant soft tissue level.
dc.description.departmentDepto. de Especialidades Clínicas Odontológicas
dc.description.departmentDepto. de Odontología Conservadora y Prótesis
dc.description.facultyFac. de Odontología
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationMartínez-Rus F, Prieto M, Salido MP, Madrigal C, Özcan M, Pradíes G. A Clinical Study Assessing the Influence of Anodized Titanium and Zirconium Dioxide Abutments and Peri-implant Soft Tissue Thickness on the Optical Outcome of Implant-Supported Lithium Disilicate Single Crowns. Int J Oral Maxillofac Implants. 2017 Jan/Feb;32(1):156-163. doi: 10.11607/jomi.5258
dc.identifier.doi10.11607/jomi.5258
dc.identifier.essn1942-4434
dc.identifier.issn0882-2786
dc.identifier.officialurlhttps://doi.org/10.11607/jomi.5258
dc.identifier.pmid28095519
dc.identifier.relatedurlhttps://www.quintessence-publishing.com/usa/en/journal/the-international-journal-of-oral-maxillofacial-implants/2017/01
dc.identifier.relatedurlhttps://pubmed.ncbi.nlm.nih.gov/28095519/
dc.identifier.urihttps://hdl.handle.net/20.500.14352/115550
dc.issue.number1
dc.journal.titleThe International journal of oral and maxillofacial implants
dc.language.isoeng
dc.page.final163
dc.page.initial156
dc.publisherQuintessence
dc.rights.accessRightsrestricted access
dc.subject.cdu616.314-089.843
dc.subject.cdu615.46
dc.subject.keywordColor
dc.subject.keywordImplant abutments
dc.subject.keywordLithium disilicate
dc.subject.keywordOral implants
dc.subject.keywordSoft tissue
dc.subject.keywordSpectrophotometer
dc.subject.keywordTitanium
dc.subject.keywordZirconia
dc.subject.ucmOdontología (Odontología)
dc.subject.ucmImplantes dentales
dc.subject.ucmMateriales dentales
dc.subject.unesco3213.13 Ortodoncia-Estomatología
dc.subject.unesco3213 Cirugía
dc.subject.unesco3312 Tecnología de Materiales
dc.titleA clinical study assessing the influence of anodized titanium and zirconium dioxide abutments and peri-implant soft tissue thickness on the optical outcome of implant-supported lithium disilicate single crowns
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number32
dspace.entity.typePublication
relation.isAuthorOfPublicationeddef645-1a65-4096-8122-07150050e03c
relation.isAuthorOfPublicationc6f6ec8c-105a-4334-a0e1-9404f1e769b8
relation.isAuthorOfPublication377d078b-3e35-4391-9e91-0483a4e68bb0
relation.isAuthorOfPublication1f9c3f08-3382-454f-8c0e-b5de6a5d271b
relation.isAuthorOfPublication.latestForDiscoveryeddef645-1a65-4096-8122-07150050e03c

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Int J Oral Maxillofac Implants. 2017 Jan/Feb;32(1):156-163.pdf
Size:
170.01 KB
Format:
Adobe Portable Document Format