Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Analysis of inner and outer retinal layers using spectral domain optical coherence tomography automated segmentation software in ocular hypertensive and glaucoma patients

dc.contributor.authorCifuentes Canorea, Pilar
dc.contributor.authorRuiz Medrano, Jorge
dc.contributor.authorGutierrez Bonet, Rosa
dc.contributor.authorPeña García, Pablo
dc.contributor.authorSáenz Francés, Federico
dc.contributor.authorGarcía Feijoo, Julián
dc.contributor.authorMartínez De La Casa Fernández-Borrella, José María
dc.dateReceived: January 13, 2018; Accepted: April 8, 2018; Published: April 19, 2018.
dc.date.accessioned2023-06-17T12:26:57Z
dc.date.available2023-06-17T12:26:57Z
dc.date.issued2018-04-19
dc.description.abstractObjective: To analyse the morphological features and diagnostic ability of eight macular retinal layers using a new segmentation software Heidelberg's Spectralis Optical Coherence Tomography (SD-OCT) in healthy, ocular hypertensive and primary open angle glaucoma patients. Methods: Single-center, cross-sectional, non-interventional study. 193 eyes from 193 consecutive patients (56 controls, 63 ocular hypertensives, 32 early primary open glaucoma patients and 42 moderate-advanced primary open glaucoma patients). Those patients presenting any retinal disease were excluded. Macular segmentation of the retinal layers was automatically performed using the new segmentation Heidelberg's Spectralis OCT software providing measurements for eight retinal layers. The software provides thickness maps divided into nine subfields. Results: Statistically significant differences in inner layers’ thickness was found between all 4 four groups. Superior and inferior sectors of macular retinal nerve fiber layer; nasal, temporal, superior and inferior sectors of ganglion cell layer and inner plexiform layer were significantly different when comparing ocular hypertensive patients and early glaucoma patients. Areas under the ROC curves for early glaucoma diagnosis were 0.781±0.052 for macular retinal nerve fiber layer outer inferior sector, 0.760±0.050 for ganglion cell layer outer temporal sector, 0.767±0.049 for the inner plexiform layer outer temporal sector and 0.807±0.048 for the combination of all three. No differences were found between groups when considering outer retinal layers. Conclusions: The automated segmentation software from Heidelberg's Spectralis OCT provides a new diagnostic tool for the diagnosis of ocular hypertensive and glaucoma patients.en
dc.description.departmentUnidad Docente de Inmunología, Oftalmología y ORL
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/47315
dc.identifier.citationCifuentes-Canorea, P., Ruiz Medrano, J., Gutierrez Bonet, R. et al. «Analysis of Inner and Outer Retinal Layers Using Spectral Domain Optical Coherence Tomography Automated Segmentation Software in Ocular Hypertensive and Glaucoma Patients». PLOS ONE, editado por Rafael Linden, vol. 13, n.o 4, abril de 2018, p. e0196112. DOI.org (Crossref), https://doi.org/10.1371/journal.pone.0196112.
dc.identifier.doi10.1371/journal.pone.0196112
dc.identifier.issn1932-6203
dc.identifier.officialurlhttps://doi.org/10.1371/journal.pone.0196112
dc.identifier.relatedurlhttp://journals.plos.org/plosone/article?id=10.1371/journal.pone.0196112
dc.identifier.relatedurlhttps://europepmc.org/abstract/med/29672563
dc.identifier.urihttps://hdl.handle.net/20.500.14352/12060
dc.issue.number0196112
dc.journal.titlePLoS ONE
dc.language.isoeng
dc.publisherPublic Library Science
dc.rightsAtribución 3.0 España
dc.rights.accessRightsopen access
dc.rights.urihttps://creativecommons.org/licenses/by/3.0/es/
dc.subject.cdu617.7-007.681
dc.subject.cdu617.735-073.75
dc.subject.keywordGlaucoma
dc.subject.keywordTomography
dc.subject.keywordOCT
dc.subject.keywordGnglion cells
dc.subject.keywordNerve fibers
dc.subject.keywordChorid
dc.subject.keywordRetinal layers
dc.subject.keywordHypertension
dc.subject.keywordOcular hipertensive patients
dc.subject.ucmOftalmología
dc.subject.ucmAnatomía ocular
dc.subject.ucmTécnicas de la imagen
dc.subject.unesco3201.09 Oftalmología
dc.titleAnalysis of inner and outer retinal layers using spectral domain optical coherence tomography automated segmentation software in ocular hypertensive and glaucoma patientsen
dc.typejournal article
dc.volume.number13
dspace.entity.typePublication
relation.isAuthorOfPublication558b8023-6d72-4dff-9f99-2e60f6f31843
relation.isAuthorOfPublication273a99c3-2c9f-4dd0-8939-b7ff3593124c
relation.isAuthorOfPublication.latestForDiscovery558b8023-6d72-4dff-9f99-2e60f6f31843

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Martínez de la Casa_ Analysis inner-Plos-2018-journal.pone.0196112.pdf
Size:
4.24 MB
Format:
Adobe Portable Document Format

Collections