Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Porosity of resin cements and resin-modified glass-ionomers

dc.contributor.authorMiguel Calvo, Alicia
dc.contributor.authorMacorra García, José Carlos De La
dc.contributor.authorNevado Rodríguez, Silvia
dc.contributor.authorGómez López, Javier
dc.date.accessioned2023-06-20T20:30:27Z
dc.date.available2023-06-20T20:30:27Z
dc.date.issued2001-02
dc.description.abstractPurpose: to quantify the internal free surface in various resin cements and glass-ionomer-based materials. Materials and methods: materials tested were Nexus fluid (NXF) and vicous (NXV), Vitremer (VTM), Fuji II LC (FII), Vitremer Luting Cement (VLC), Dyract (DYR) and Compoglass (COM). Samples (n=5) were made of each material between two microscopic glass slides under same weight. With a transmitted light microscopy, four zones of each sample were evaluated, finding the number of porosities per mm² (NP), the average radius of porosities (RP), the ratio of total area of surface porosities (µ²) to area (mm²) of specimen surface (TA) and the ratio of total volume of porosities (µ²) to area (mm²) of material surface (VP). Results: median test was used. NP: NXV, NXF and DYR had smaller than VTM and FII ans (likely) than VLC (P<0.0000001) RP was smaller for DYR than for VLC and (likely) than for NXV (P=0.00019). TA: NXV, NXF and DYR had smaller TA than VTM, FII and VLC (P<0.0000001). VP: NXV and DYR had smaller VP than FII and (likely) than VTM and VLC (P<0.0000001).en
dc.description.departmentDepto. de Odontología Conservadora y Prótesis
dc.description.facultyFac. de Odontología
dc.description.refereedTRUE
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/5055
dc.identifier.issn0894-8275
dc.identifier.urihttps://hdl.handle.net/20.500.14352/60376
dc.issue.number1
dc.journal.titleAmerican Journal of Dentistry
dc.language.isospa
dc.page.final21
dc.page.initial17
dc.rights.accessRightsopen access
dc.subject.ucmMateriales dentales
dc.subject.unesco3213.13 Ortodoncia-Estomatología
dc.titlePorosity of resin cements and resin-modified glass-ionomersen
dc.typejournal article
dc.volume.number14
dspace.entity.typePublication
relation.isAuthorOfPublicationf5333c8f-81c3-45e2-8b6e-599c7e530561
relation.isAuthorOfPublication0b38ba8d-c9aa-404d-8ec6-b8c2d6a78884
relation.isAuthorOfPublication.latestForDiscoveryf5333c8f-81c3-45e2-8b6e-599c7e530561

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Porosity_of_resin_cements_and_resin-modified_glass-ionomers.pdf
Size:
1.82 MB
Format:
Adobe Portable Document Format

Collections