Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

First Results after Implantation of Hydrophilic and Hydrophobic Trifocal Intraocular Lenses: Visual and Optical Performance

dc.contributor.authorPoyales Galán, Francisco
dc.contributor.authorPérez Izquierdo, Ricardo
dc.contributor.authorLópez Brea, Israel
dc.contributor.authorZhou, Ying
dc.contributor.authorGarzón Jiménez, Nuria
dc.date.accessioned2023-06-16T14:18:05Z
dc.date.available2023-06-16T14:18:05Z
dc.date.issued2021-12-18
dc.descriptionReceived 2 May 2021; Accepted 22 November 2021
dc.description.abstractPurpose. To compare postcataract surgery visual and optical performance between two trifocal intraocular lenses (IOLs) with the same optical design: a hydrophobic acrylic glistening-free IOL and a hydrophilic acrylic IOL. Methods. Patients were bilaterally implanted with either the hydrophobic or the hydrophilic IOL. The data of the patients’ right eyes were evaluated. Visual quality assessments included refractive outcomes, monocular visual acuity (VA) at far, intermediate, and near distances, defocus curve, aberrations (spherical aberration (SA)), root mean square (RMS) of corneal, internal, and total higher-order aberrations (HOAs)), and tilt of IOL. Results. Fifty-one patients were included in the analysis: 26 patients implanted with the hydrophobic IOL and 25 patients implanted with the hydrophilic IOL. At 1 month, no statistically significant differences were found for monocular uncorrected and corrected VA at distance, distance-corrected VA at intermediate and near, defocus curve, manifest spherical equivalent, total SA, and RMS of the total, internal, and corneal HOA. The defocus curve of both groups showed a visual acuity of 0.3 logMAR or better in the intermediate range from 0.5 to −2.5 D of vergence level with no significant differences between the groups. Compared to the hydrophilic group, y-direction tilt was significantly higher in the hydrophobic group (p=0.027). The total tilt and x-axis tilt did not differ between the groups. Conclusion. Both IOLs demonstrated an excellent quality of vision and provided the patient with a wide range of vision.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/69292
dc.identifier.doi10.1155/2021/3514577
dc.identifier.issn2090-004X
dc.identifier.officialurlhttps://doi.org/10.1155/2021/3514577
dc.identifier.relatedurlhttps://www.hindawi.com/journals/joph/2021/3514577/
dc.identifier.urihttps://hdl.handle.net/20.500.14352/4585
dc.journal.titleJournal of Ophthalmology
dc.language.isoeng
dc.page.final8 p.
dc.page.initialart. 3514577
dc.publisherHindawi Publishing Corporation
dc.rightsAtribución 3.0 España
dc.rights.accessRightsopen access
dc.rights.urihttps://creativecommons.org/licenses/by/3.0/es/
dc.subject.cdu617.751
dc.subject.cdu681.735
dc.subject.cdu681.7.066
dc.subject.cdu617.741-004.1-089
dc.subject.keywordFirst Results after Implantation of Hydrophilic and Hydrophobic Trifocal Intraocular Lenses
dc.subject.keywordIntraocular lenses
dc.subject.keywordOptical performance
dc.subject.keywordPostcataract surgery
dc.subject.ucmCirugía
dc.subject.ucmOftalmología
dc.subject.ucmOptometría
dc.subject.ucmÓptica oftálmica
dc.subject.unesco3213 Cirugía
dc.subject.unesco3201.09 Oftalmología
dc.subject.unesco2209.15 Optometría
dc.titleFirst Results after Implantation of Hydrophilic and Hydrophobic Trifocal Intraocular Lenses: Visual and Optical Performance
dc.typejournal article
dc.volume.number2021
dspace.entity.typePublication
relation.isAuthorOfPublication367ce491-287f-4b2a-ba6a-870a393c5609
relation.isAuthorOfPublication.latestForDiscovery367ce491-287f-4b2a-ba6a-870a393c5609

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
3514577.pdf
Size:
1.23 MB
Format:
Adobe Portable Document Format

Collections