Three-dimensional color doppler transesophageal echocardiography for mitral paravalvular leak quantification and evaluation of percutaneous closure success

dc.contributor.authorFranco, Eduardo
dc.contributor.authorAlmería, Carlos
dc.contributor.authorDe Agustín Loeches, José Alberto
dc.contributor.authorArreo del Val, Viviana
dc.contributor.authorGómez de Diego, José Juan
dc.contributor.authorGarcía Fernández, Miguel Ángel
dc.contributor.authorMacaya Miguel, Carlos
dc.contributor.authorPérez De Isla, Leopoldo
dc.contributor.authorGarcia, Eulogio
dc.date.accessioned2026-02-02T12:46:46Z
dc.date.available2026-02-02T12:46:46Z
dc.date.issued2014
dc.description.abstractBackground: Three-dimensional (3D) color Doppler transesophageal echocardiography (TEE) enables accurate planimetry of the effective regurgitant orifice (ERO) of a mitral paravalvular leak (PVL). The aim of this study was to evaluate the usefulness of this method to quantify paravalvular regurgitation and to assess percutaneous PVL closure success, compared with 3D planimetry of PVLs without using color-flow images (3D anatomic regurgitant orifice [ARO]). Methods: Forty-six patients (59 mitral PVLs) who underwent 3D TEE to evaluate the indication of PVL closure procedure were retrospectively included. Receiver operating characteristic curves were compared to identify degree III and IV paravalvular regurgitation of 3D color ERO and 3D ARO measures. Forty patients underwent percutaneous PVL closure procedures; analysis was conducted to determine whether the undersizing of the closure devices according to 3D color ERO and 3D ARO measures was associated with PVL closure failure. Results: Three-dimensional ERO measures showed better areas under the curve than 3D ARO measures and correlated better with the degree of paravalvular regurgitation. Three-dimensional color ERO major diameter ≥ 0.65 cm showed a positive predictive value of 87.1% and a negative predictive value of 94% to diagnose degree III and IV paravalvular regurgitation. For the 40 patients who underwent PVL closure procedures, the immediate technical success rate was 76.9%, and 1-year estimated survival was 69.5%. Closure device undersizing according to 3D color ERO length, but not other PVL measurements, was significantly associated with PVL closure failure (P = .007). Conclusion: Three-dimensional ERO was superior to 3D ARO at identifying the presence of degree III and IV paravalvular regurgitation. The undersizing of closure devices according to 3D color ERO length was associated with failed closure procedures. Confirmatory prospective studies are encouraged.
dc.description.departmentDepto. de Medicina
dc.description.facultyFac. de Medicina
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationFranco, E., Almería, C., de Agustín, J. A., Arreo Del Val, V., Gómez de Diego, J. J., García Fernández, M. Á., Macaya, C., Pérez de Isla, L., & Garcia, E. (2014). Three-dimensional color Doppler transesophageal echocardiography for mitral paravalvular leak quantification and evaluation of percutaneous closure success. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography, 27(11), 1153–1163. https://doi.org/10.1016/j.echo.2014.08.019
dc.identifier.doi10.1016/J.ECHO.2014.08.019
dc.identifier.issn1097-6795
dc.identifier.officialurlhttps://doi.org/10.1016/J.ECHO.2014.08.019
dc.identifier.pmid25260434
dc.identifier.relatedurlhttps://www.sciencedirect.com/journal/journal-of-the-american-society-of-echocardiography
dc.identifier.urihttps://hdl.handle.net/20.500.14352/131357
dc.issue.number11
dc.journal.titleJournal of the American Society of Echocardiography
dc.language.isoeng
dc.page.final1163
dc.page.initial1153
dc.publisherElsevier
dc.rights.accessRightsrestricted access
dc.subject.cdu616.12
dc.subject.keywordParavalvular leak, Three-dimensional transesophageal echocardiography, Paravalvular mitral regurgitation, Effective regurgitant orifice, Percutaneous paravalvular leak closure procedure
dc.subject.ucmCardiología
dc.subject.unesco3205.01 Cardiología
dc.titleThree-dimensional color doppler transesophageal echocardiography for mitral paravalvular leak quantification and evaluation of percutaneous closure success
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number27
dspace.entity.typePublication
relation.isAuthorOfPublicationa4d160b9-b06d-4e03-8aa8-fb88af3fe61b
relation.isAuthorOfPublication5d7a61fe-bda8-40d7-bbe6-98cf64177dd4
relation.isAuthorOfPublicationb775562d-8fda-4abe-aaf2-fd622b25a3e8
relation.isAuthorOfPublication395641a3-ea72-4613-a2f3-85fbf86fae29
relation.isAuthorOfPublication.latestForDiscoverya4d160b9-b06d-4e03-8aa8-fb88af3fe61b

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1-s2.0-S0894731714006130.pdf
Size:
1.72 MB
Format:
Adobe Portable Document Format
Description:
Versión publicada. Copyright de la editorial.

Collections