Person:
Pastrana Robles, Cristina

Loading...
Profile Picture
First Name
Cristina
Last Name
Pastrana Robles
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Óptica y Optometría
Department
Optometría y Visión
Area
Optica
Identifiers
UCM identifierORCIDScopus Author IDWeb of Science ResearcherIDDialnet ID

Search Results

Now showing 1 - 10 of 14
  • Item
    Accuracy and precision of automated subjective refraction in young hyperopes under cycloplegia
    (Journal of Optometry, 2023) Carracedo Rodríguez, Juan Gonzalo; Carpena Torres, Carlos; Pastrana Robles, Cristina; Rodríguez -Lafora Lorente, María; Serramito Blanco, María; Privado Aroco, Ana; Espinosa Vidal, Teresa M.
    Purpose: To assess the agreement between the Eye Refract, an instrument to perform subjective automated refraction, and the traditional subjective refraction, as the gold standard, in young hyperopes under noncycloplegic and cycloplegic conditions. Methods: A cross-section and randomized study was carried out, involving 42 participants (18.2 ± 7.7 years, range 6 to 31 years). Only one eye was chosen for the analysis, randomly. An optometrist conducted the refraction with the Eye Refract, while another different optometrist conducted the traditional subjective refraction. Spherical equivalent (M), cylindrical components (J0 and J45), and corrected distance visual acuity (CDVA) were compared between both refraction methods under noncycloplegic and cycloplegic conditions. A Bland-Altman analysis was performed to assess the agreement (accuracy and precision) between both refraction methods. Results: Without cycloplegia, the Eye Refract showed significantly lower values of hyperopia than the traditional subjective refraction (p < 0.009), the mean difference (accuracy) and its 95% limits of agreement (precision) being -0.31 (+0.85, -1.47) D. Conversely, there were no statistical differences between both refraction methods under cycloplegic conditions (p ≥ 0.05). Regarding J0 and J45, both refraction methods manifested no significant differences between them under noncycloplegic and cycloplegic conditions (p ≥ 0.05). Finally, the Eye Refract significantly improved CDVA (0.04 ± 0.01 logMAR) compared with the traditional subjective refraction without cycloplegia (p = 0.01). Conclusions: The Eye Refract is presented as a useful instrument to determine the refractive error in young hyperopes, the use of cycloplegia being necessary to obtain accurate and precise spherical refraction.
  • Item
    A Comparison between Automated Subjective Refraction and Traditional Subjective Refraction in Keratoconus Patients
    (Optometry and Vision Science, 2021) Carracedo Rodríguez, Juan Gonzalo; Carpena Torres, Carlos; Pastrana Robles, Cristina; Privado Aroco, Ana; Serramito Blanco, María; Espinosa Vidal, Teresa M.; Rodríguez-Lafora Lorente, María
    SIGNIFICANCE: The performance of the Eye Refract (Luneau Technology, Chartres, France), a new instrument to perform aberrometry-based automated subjective refraction, has been previously evaluated in healthy subjects. However, its clinical implications in other ocular conditions are still unknown. PURPOSE: The purpose of this study was to evaluate the agreement between the Eye Refract and the traditional subjective refraction, as the criterion standard, in keratoconus patients with and without intracorneal ring segments (ICRSs). METHODS: A total of 50 eyes of 50 keratoconus patients were evaluated, dividing the sample into 2 groups: 27 eyes without ICRS (37.78 ± 9.35 years) and 23 eyes with ICRS (39.26 ± 13.62 years). An optometrist conducted the refraction with the Eye Refract, and another different optometrist conducted the traditional subjective refraction on the same day. Spherical equivalent (M), cylindrical vectors (J0 and J45), and corrected distance visual acuity were compared between both methods of refraction. In addition, Bland-Altman analysis was performed to assess the agreement between both methods of refraction. RESULTS: There were no statistically significant differences (P ≥ .05) between the Eye Refract and the traditional subjective refraction for all the variables under study in either group. Without ICRS, the mean difference and 95% limits of agreement (upper, lower) were −0.20 (+1.50, −1.89) D for M, −0.14 (+1.40, −1.68) D for J0, and +0.05 (+1.23, −1.14) D for J45. With ICRS, these values worsened to −0.62 (+3.89, −5.12) D for M, +0.06 (+2.46, −2.34) D for J0, and −0.02 (+2.23, −2.28) D for J45. CONCLUSIONS: The Eye Refract seems to offer similar results compared with the traditional subjective refraction in keratoconus patients not implanted with ICRS. However, some patients could show abnormal measurements, especially those with ICRS, who should be treated with caution in clinical practice.
  • Item
    Dual-Mode Gold Nanoparticle-Based Method for Early Detection of Acanthamoeba
    (International Journal of Molecular Sciences, 2022) Pastrana Robles, Cristina; Guerreiro, Joana Rafaela L.; Elumalai, Monisha; Carpena Torres, Carlos; Crooke Álvarez, Almudena; Carracedo Rodríguez, Juan Gonzalo; Prado, Marta; Huete Toral, Fernando
    Acanthamoeba keratitis is an aggressive and rapidly progressing ocular pathology whose main risk factor is the use of contact lenses. An early and differential diagnosis is considered the main factor to prevent the progression and improve the prognosis of the pathology. However, current diagnosis techniques require time, complex and costly materials making an early diagnosis challenging. Thus, there is a need for fast, accessible, and accurate methods for Acanthamoeba detection by practitioners for timely and suitable treatment and even for contact lens user as preventive diagnosis. Here, we developed a dual-mode colorimetric-based method for fast, visual, and accurate detection of Acanthamoeba using gold nanoparticles (AuNPs). For this strategy, AuNPs were functionalized with thiolated probes and the presence of target Acanthamoeba genomic sequences, produce a colorimetric change from red to purple. This approach allows the detection of 0.02 and 0.009 μM of the unamplified Acanthamoeba genome by the naked eye in less than 20 min and by color analysis using a smartphone. Additionally, real samples were successfully analyzed showing the potential of the technology considering the lack of point-of-care tools that are mostly needed.
  • Item
    Contact Lenses as Drug Delivery System for Glaucoma: A Review
    (Applied sciences, 2020) Peral Cerda, María Asunción; Martínez Águila, Alejandro; Pastrana Robles, Cristina; Huete Toral, Fernando; Carpena Torres, Carlos; Carracedo Rodríguez, Juan Gonzalo
    Glaucoma is an optical neuropathy associated to a progressive degeneration of retinal ganglion cells with visual field loss and is the main cause of irreversible blindness in the world. The treatment has the aim to reduce intraocular pressure. The first therapy option is to instill drugs on the ocular surface. The main limitation of this is the reduced time of the drug staying on the cornea. This means that high doses are required to ensure its therapeutic effect. A drug-loaded contact lens can diffuse into the post lens tear film in a constant and prolonged flow, resulting in an increased retention of the drug on the surface of the cornea for up to 30 min and thus providing a higher drug bioavailability, increasing the therapeutic efficacy, reducing the amount of administered drug, and thereby provoking fewer adverse events. Several different systems of drug delivery have been studied in recent decades; ranging from more simple methods of impregnating the lenses, such as soaking, to more complex ones, such as molecular imprinting have been proposed. Moreover, different drugs, from those already commercially available to new substances such as melatonin have been studied to improve the glaucoma treatment efficacy. This review describes the role of contact lenses as an innovative drug delivery system to treat glaucoma.
  • Item
    Presence of melatonin in human tears
    (Journal of Optometry, 2016) Carracedo Rodríguez, Juan Gonzalo; Carpena Torres, Carlos; Concepción Cuevas, Eugenio Pablo; Díaz, Victor; García-García, Miguel; Jemnic, Nahla; Lledó Mayans, Victoria Eugenia; Martín, Marina; Pastrana Robles, Cristina; Pelissier, Raquel; Veselinova, Albena; Wang, Xiaoyu; Pintor Just, Jesús Jerónimo
  • Item
    Optimization of a Rabbit Dry Eye Model Induced by Topical Instillation of Benzalkonium Chloride
    (Journal of Ophthalmology, 2020) Carpena Torres, Carlos; Pintor Just, Jesús Jerónimo; Pérez de Lara, María Jesús; Huete Toral, Fernando; Crooke Álvarez, Almudena; Pastrana Robles, Cristina; Carracedo Rodríguez, Juan Gonzalo
    Purpose. To optimize a rabbit dry eye model induced by topical instillation of benzalkonium chloride (BAC), reduce the days of instillation of the original model by increasing the concentration of BAC from 0.1% to 0.2%. Materials and Methods. An experimental, prospective, and randomized study was performed on 10 male New Zealand white rabbits, divided into two groups, considering both eyes: 5 rabbits as control (n = 10) and 5 rabbits with 0.2% BAC treatment (n = 10). Saline solution (control) and 0.2% BAC were instilled for 5 consecutive days, twice daily. Tear secretion with and without anesthesia, tear breakup time, tear osmolarity, corneal staining, conjunctival hyperemia, density of goblet cells, height of mucin cloud, and transcript levels of IL-6 were measured before and after the treatment. Results. After the instillation of 0.2% BAC for 5 consecutive days, there was a significant increase in tear secretion without anesthesia (P < 0.001), corneal staining (P < 0.001), conjunctival hyperemia (P < 0.001), and levels of IL-6 mRNA (P = 0.005) compared to the control group. Conversely, there was a decrease in tear secretion with anesthesia (P < 0.001), tear breakup time (P = 0.007), tear osmolarity (P < 0.001), density of goblet cells (P < 0.001), and height of mucin cloud (P < 0.001). Conclusions. )e topical instillation of 0.2% BAC for 5 consecutive days, twice daily, was a proper procedure to induce a rabbit dry eye model, reducing the number of days of instillation compared to the original model (14 days).
  • Item
    PhDAY 2020 -FOO (Facultad de Óptica y Optometría)
    (2020) Pintor Just, Jesús Jerónimo; Carpena Torres, Carlos; Peral Cerda, María Asunción; Pérez de Lara, María Jesús; Toral, Fernando; Crooke Álvarez, Almudena; Pastrana Robles, Cristina; Carracedo Rodríguez, Juan Gonzalo; Cayuela López, Ana; Sorzano Sánchez, Óscar; Charbel, Carla; Garzón Jiménez, Nuria; Carballo Álvarez, Jesús; Diz Arias, Elena; Fernández Jiménez, Elena; Lledó Mayans, Victoria Eugenia; Gómez Pedrero, José Antonio; Durán Prieto, Elena; López Alonso, José Manuel; Fernández Torres, Miguel Ángel; Guzmán Aránguez, Ana Isabel; Gómez Manzanares, Ángela; Vázquez Molini, Daniel; Martínez Antón, Juan Carlos; Bernárdez Vilaboa, Ricardo; Mayorga Pinilla, Santiago; Álvarez Fernández-Balbuena, Antonio; Benítez, AntoJ.; Igalla El-Youssfi, Asmae; León Álvarez, Alejandro; Palomo Álvarez, Catalina; Awad Alkozi, Hanan; Sánchez Naves, Juan; Martínez Alberquilla, Irene; García Montero, María; Ruiz Alcocer, Javier; Madrid Costa, David; Martínez Florentín, Gema; Papas, Eric B.; Medrano Muñoz, Sandra Milena; Molina, Nancy; Jurado, Sandra; Oliveiros López, Juan; Platero Alvarado, Nadiuska Cristine; Garrido Mercado, Rafaela; Pérez Garmendia, Carlos; Antona Peñalba, Beatriz; Barrio De Santos, Ana Rosa; González Pérez, Mariano; Pérez Garmendia, Carlos; Serramito Blanco, María; Privado Aroco, Ana; Almalki, Wael; Bodas Romero, Julia; Ouzzani, Mohamed; Paune, Jaume; Calderón García, Raquel; Pitarch Velasco, Aída; Cebrián, José Luis; Sánchez Pérez, María Isabel; García Rojo, Marta María; Bonnin Arias, Cristina Natalia; Sánchez Ramos, Celia; Gutiérrez Jorrín, Sara Carmen; Rodríguez Alonso, Xabier; Laucirica Sáenz, Gorka; Arranz Márquez, Esther; Alonso Castellanos, Miriam; Teus Guezala, Miguel Ángel; Hernández Verdejo, José Luis; Mármol Errasti, Esther; Martín García, Beatriz; Arriola Villalobos, Pedro; Gómez De Liaño Sánchez, María Rosario; Mínguez Caro, N; Orduña Azcona, Javier; Navarro Gil, Francisco Javier; Huete Toral, Fernando; Rodríguez Pomar, Candela; Martínez Águila, Alejandro; Martín Gil, Alba; Tomé de la Torre, Miguel Ángel
    Por cuarto año consecutivo los doctorandos de la Facultad de Óptica y Optometría de la Universidad Complutense de Madrid cuentan con un congreso propio organizado por y para ellos, el 4º PhDAY- FOO. Se trata de un congreso gratuito abierto en la que estos jóvenes científicos podrán presentar sus investigaciones al resto de sus compañeros predoctorales y a toda la comunidad universitaria que quiera disfrutar de este evento. Apunta en tu agenda: el 15 de octubre de 2020. En esta ocasión será un Congreso On-line para evitar que la incertidumbre asociada a la pandemia Covid-19 pudiera condicionar su celebración.
  • Item
    Changes in visual quality with soft contact lenses after the instillation of hyaluronic acid eye drops
    (Contact Lens & Anterior Eye, 2021) Carpena Torres, Carlos; Pastrana Robles, Cristina; Rodríguez Pomar, Candela; Serramito Blanco, María; Batres Valderas, Laura; Carracedo Rodríguez, Juan Gonzalo
    Purpose: To evaluate the changes in visual function and anterior surface aberrations during soft contact lens (SCL) wear after the instillation of hyaluronic acid (HA) eye drops with different viscosity. Methods: A prospective, randomized, and participant-masked study was performed. Twenty healthy participants (25.4 ± 2.6 years) were evaluated. Hydrogel (Ocufilcon D) and silicone-hydrogel (Somofilcon A) SCL were randomly assigned to both eyes of the same participant. Visual function in terms of high- and low-contrast corrected distance visual acuity (CDVA) and anterior contact lens surface aberrations (RMS HOA) were measured before and after the instillation, at different times, of different eye drops: saline (control) and 0.1%, 0.2%, and 0.3% HA. Results: Compared with the saline solution, during hydrogel SCL wear, there was an improvement (P < 0.05) in high-contrast CDVA after 3 and 10 min with 0.1% HA, and after 5 and 20 min with 0.2% HA. During silicone�hydrogel SCL wear, there was a deterioration (P < 0.05) in high-contrast CDVA after 1 and 30 min with 0.3% HA. Additionally, during silicone-hydrogel SCL wear, there was also a deterioration (P < 0.05) in low-contrast CDVA after 5 and 20 min with 0.3% HA. In terms of RMS HOA, there were no clinically relevant changes with both SCL. Conclusions: The instillation of HA eye drops could have a different effect on visual quality depending on their concentration of HA, the contact lens material, its surface ionicity, or other physicochemical properties that should be studied in future studies.
  • Item
    From oxidative stress to inflammation in the posterior ocular diseases: Diagnosis and treatment
    (Pharmaceutics, 2021) Dammak, Azza; Huete Toral, Fernando; Carpena Torres, Carlos; Martín Gil, Alba; Pastrana Robles, Cristina; Carracedo Rodríguez, Juan Gonzalo
    Most irreversible blindness observed with glaucoma and retina-related ocular diseases, including age-related macular degeneration and diabetic retinopathy, have their origin in the posterior segment of the eye, making their physiopathology both complex and interconnected. In addition to the age factor, these diseases share the same mechanism disorder based essentially on oxidative stress. In this context, the imbalance between the production of reactive oxygen species (ROS) mainly by mitochondria and their elimination by protective mechanisms leads to chronic inflammation. Oxidative stress and inflammation share a close pathophysiological process, appearing simultaneously and suggesting a relationship between both mechanisms. The biochemical end point of these two biological alarming systems is the release of different biomarkers that can be used in the diagnosis. Furthermore, oxidative stress, initiating in the vulnerable tissue of the posterior segment, is closely related to mitochondrial dysfunction, apoptosis, autophagy dysfunction, and inflammation, which are involved in each disease progression. In this review, we have analyzed (1) the oxidative stress and inflammatory processes in the back of the eye, (2) the importance of biomarkers, detected in systemic or ocular fluids, for the diagnosis of eye diseases based on recent studies, and (3) the treatment of posterior ocular diseases, based on long-term clinical studies.
  • Item
    Stabilization of comfort and visual quality after the insertion of soft contact lenses
    (Contact Lens and Anterior Eye, 2021) Carpena Torres, Carlos; Pastrana Robles, Cristina; Rodríguez Pomar, Candela; Serramito Blanco, María; Carracedo Rodríguez, Juan Gonzalo
    Purpose: To evaluate comfort, visual function, and in vivo wettability after the insertion of hydrogel and silicone hydrogel contact lenses for a better understanding of how long practitioners should wait for the initial evaluation of soft contact lenses. Methods: A short-term prospective, contralateral, randomized, and participant-masked study was carried out. Twenty healthy participants (25.4 ± 2.6 years) were evaluated after the insertion of two different soft contact lenses at different times (1, 5, 10, 20, 30 min). Ocufilcon D (hydrogel) and Somofilcon A (silicone hydrogel) contact lenses were randomly assigned to both eyes of the same participant. Comfort, visual function under photopic conditions in terms of high-contrast visual acuity, low-contrast visual acuity, contrast sensitivity, and in vivo wettability were measured. Results: There was an increase in comfort (p < 0.001), high-contrast visual acuity (p < 0.05), and contrast sensitivity (p < 0.001, only with silicone hydrogel) directly related to time after contact lens insertion. Besides, in vivo wettability suffered a statistically significant deterioration directly related to time with both contact lenses (p < 0.05). Except for comfort and contrast sensitivity, all the parameters stabilized their values 10 min after the insertion of both soft contact lenses. Additionally, in vivo wettability and visual acuity differences were found between hydrogel and silicone hydrogel contact lenses (p < 0.05). Conclusions: It would be possible to properly evaluate high-contrast visual acuity, low-contrast visual acuity, and in vivo wettability 10 min after the insertion of both soft contact lenses.