Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Análisis del comportamiento mecánico de dos implantes con diferente nivel y diseño de la conexión protésica, ante coronas atornilladas de distinta longitud. Estudio in vitro

dc.contributor.advisorPradíes Ramiro, Guillermo Jesús
dc.contributor.advisorBartolomé Gómez, José Florindo
dc.contributor.authorPérez León, Patricia
dc.date.accessioned2023-06-17T16:08:05Z
dc.date.available2023-06-17T16:08:05Z
dc.date.defense2017-11-27
dc.date.issued2018-10-24
dc.descriptionTesis inédita de la Universidad Complutense de Madrid de la Facultad de Odontología del Departamento de Estomatología I (Prótesis Bucofacial ), leída el 27 de Noviembre de 2017.es
dc.description.abstractEl tratamiento con implantes dentales osteointegrados representa una opción terapéutica validada científica y clínicamente para la rehabilitación funcional y estética de los pacientes. A pesar de que las prótesis implanto-soportadas han demostrado altas tasas de éxito a largo plazo, se han reportado distintas complicaciones biológicas, mecánicas, estéticas, etc. En relación con las mecánicas, gran número de estudios demuestran que el aflojamiento y fractura de tornillos de retención del pilar o de la prótesis por fatiga son las complicaciones más frecuentes en las restauraciones atornilladas, especialmente en restauraciones unitarias en la zona de molares y premolares. Las complicaciones mecánicas están frecuentemente relacionadas con los materiales y el diseño de los componentes protésicos. Además, los estudios sugieren que pueden estar determinadas por factores como el diseño de la conexión implantaria, geometría de los componentes, procedimientos de fabricación, ajustes entre los componentes, superficie del tornillo, etc. También variables dependientes del operador como la falta de verificación de ajustes pasivos, aplicación incorrecta del torque, falta de pericia técnica, etc., pueden condicionar el éxito final del conjunto implanto protésico. Por otro lado, determinadas características del paciente se han descrito clásicamente como factores de riesgo de complicaciones mecánicas y biológicas. Entre éstas, cabe destacar la presencia de hábitos parafuncionales capaces de generar fuerzas oclusales desfavorables...es
dc.description.abstractOsseointegrated dental implants represent a scientifically and clinically validated therapeutic treatment option for a functional and aesthetic restoration in patients. Although implant-supported prostheses have demonstrated long-term success rates, different biological, mechanical and esthetic complications have been reported. Regarding to mechanical complications, many studies have reported that the loosening and fatigue fracture of the abutment or prostheses screw are the most common failure modes for screw-retained prostheses especially in single implant-supported restorations in the premolar and molar region. Mechanical problems are mostly related to the materials and design of prosthetic components.Moreover, studies have suggested that these complications might be determined by different factors such as the implant connection design, the geometric design of components, the production processes, interface fits, screw surface, etc. Furthermore, variables induced by the operator such as absence of verification of passive fit, failures in the screw tightening, the lack of technical expertise, etc. may interfere with the proper operation of implant-prosthetic restoration. On the other hand, several patient characteristics have been consistently reported as a risk factor for biological and mechanical complications. These factors include parafunctional activity by generating unfavorable occlusal forces...en
dc.description.departmentDepto. de Odontología Conservadora y Prótesis
dc.description.facultyFac. de Odontología
dc.description.refereedTRUE
dc.description.statusunpub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/49695
dc.identifier.urihttps://hdl.handle.net/20.500.14352/16439
dc.language.isospa
dc.page.total204
dc.publication.placeMadrid, España
dc.publisherUniversidad Complutense de Madrid
dc.rights.accessRightsopen access
dc.subject.cdu616.314-089.28(043.2)
dc.subject.cdu616.314-089.843(043.2)
dc.subject.keywordImplantes dentales
dc.subject.keywordPrótesis dentales
dc.subject.keywordDental implants
dc.subject.keywordDental prostheses
dc.subject.ucmImplantes dentales
dc.subject.ucmPrótesis dental
dc.subject.unesco3213.13 Ortodoncia-Estomatología
dc.subject.unesco3314.02 Prótesis
dc.titleAnálisis del comportamiento mecánico de dos implantes con diferente nivel y diseño de la conexión protésica, ante coronas atornilladas de distinta longitud. Estudio in vitroes
dc.title.alternativeAnalysis of mechanical behavior of dental implants with different design and prosthetic connection level and different lengths of screw-retained restorations. An in vitro studyen
dc.typedoctoral thesis
dspace.entity.typePublication
relation.isAdvisorOfPublication1f9c3f08-3382-454f-8c0e-b5de6a5d271b
relation.isAdvisorOfPublication.latestForDiscovery1f9c3f08-3382-454f-8c0e-b5de6a5d271b

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
T40465.pdf
Size:
16.04 MB
Format:
Adobe Portable Document Format

Collections