dc.description.abstractBackground: Due to the importance of choroidal thickness in the development of myopia, this study examined the effect of MiSight contact lenses (CLs) on the choroidal thickness of myopic children and the differences between responders and non-responders to the treatment with these CLs. Methods: A total of 41 myopic children were fitted with MiSight CLs and 33 with single-vision spectacles. They were followed up for two years. Subfoveal choroidal thickness and choroidal thickness 1 and 3 mm temporal and nasal to the fovea were measured by OCT at baseline and one and two years after the treatment. Differences in all the choroidal thickness parameters were assessed in each group over time. Patients from the MiSight group were classified based on a specific range of changes in axial length at the end of the second year of treatment as “responders” (AL change < 0.22 mm/per year) and “non-responders”, and the choroidal thickness of both groups was analyzed. Results: The subfoveal choroidal thickness of the MiSight and single-vision spectacle groups did not show any changes over time. Wearing MiSight CLs induced relative choroidal thickening in the responder group in the first year of treatment. Conclusion: Choroidal thickness might work as a predictor of the effectiveness of MiSight in myopia treatment.en
dc.description.departmentDepto. de Medicina
dc.description.facultyFac. de Óptica y Optometría
dc.description.facultyFac. de Medicina
dc.description.refereedTRUE
dc.description.sponsorshipHospital Universitario Infanta Sofía (España)
dc.description.sponsorshipFundación para la Investigación Biomédica del Hospital Universitario Ramón y Cajal (España)
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/73671
dc.identifier.doi10.3390/jcm11133833
dc.identifier.issn2077-0383
dc.identifier.officialurlhttps://doi.org/10.3390/jcm11133833
dc.identifier.relatedurlhttps://www.mdpi.com/2077-0383/11/13/3833/htm
dc.identifier.urihttps://hdl.handle.net/20.500.14352/71808
dc.issue.number13
dc.journal.titleJournal of Clinical Medicine
dc.language.isoeng
dc.page.final3833-10
dc.page.initial3833-1
dc.publisherMPDI
dc.rightsAttribution 4.0 International
dc.rights.accessRightsopen access
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subject.cdu617.753.2
dc.subject.keywordMiSight
dc.subject.keywordMyopia
dc.subject.keywordChoroidal thickness
dc.subject.keywordContact lenses
dc.subject.ucmLentes de contacto
dc.subject.ucmÓptica oftálmica
dc.subject.ucmÓptica y optometría
dc.subject.unesco3311.11 Instrumentos ópticos
dc.subject.unesco2209.15 Optometría
dc.titleChanges in the Choroidal Thickness of Children Wearing MiSight to Control Myopia
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number11
dspace.entity.typePublication
relation.isAuthorOfPublication31bb7f17-8d1c-421a-8466-0bd67952c9ba
relation.isAuthorOfPublication2ed110d3-f335-4688-9c14-1a56e56e8d28
relation.isAuthorOfPublicationdd75532a-6964-4579-bbb1-671f827cc2d2
relation.isAuthorOfPublicationb3b73bf5-22d0-4ad1-aec0-dd315db108a0
relation.isAuthorOfPublication.latestForDiscovery31bb7f17-8d1c-421a-8466-0bd67952c9ba
Download
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
jcm-11-03833-v2.pdf
Size:
1.35 MB
Format:
Adobe Portable Document Format
Collections