Para depositar en Docta Complutense, identifícate con tu correo @ucm.es en el SSO institucional. Haz clic en el desplegable de INICIO DE SESIÓN situado en la parte superior derecha de la pantalla. Introduce tu correo electrónico y tu contraseña de la UCM y haz clic en el botón MI CUENTA UCM, no autenticación con contraseña.

Drain temperature dependence on ambient temperature for a cryogenic low noise C-band amplifier

Loading...
Thumbnail Image

Full text at PDC

Publication date

1997

Advisors (or tutors)

Editors

Journal Title

Journal ISSN

Volume Title

Publisher

IEEE
Citations
Google Scholar

Citation

Abstract

A comparison between predicted and measured noise temperatures for cryogenic HEMT amplifiers is presented by using the Pospieszalski's noise model. A good agreement between predicted and measured amplifier's noise performance is obtained both at room and cryogenic temperatures. However, the predicted values overestimate noise temperature in the center part of the measured temperature range (50K - 230K). A parabolic dependence for the drain temperature with ambient temperature is proposed to obtain a better fitting to the experimental results.