Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Clinical study comparing the accuracy of interocclusal records, digitally obtained by three diferent devices

dc.contributor.authorFraile Benítez, Cristina
dc.contributor.authorFerreiroa Navarro, Alberto
dc.contributor.authorRomeo Rubio, Marta
dc.contributor.authorAlonso, Raquel
dc.contributor.authorPradíes Ramiro, Guillermo Jesús
dc.date.accessioned2024-01-31T09:27:48Z
dc.date.available2024-01-31T09:27:48Z
dc.date.issued2021-05
dc.description.abstractObjective: The aim of the present cross-sectional study was to compare the interocclusal contact records obtained by three different digital methods (intra- and extraoral digital scanners and T-Scan III system) with the conventional method (articulating paper). Materials and methods: Twenty-five healthy volunteers were selected. As a control group, maximum intercuspation occlusal contacts were registered and photographed from the patients with an 8 µm articulating paper. Then, intraoral conventional elastomer impressions were taken and after obtaining the corresponding plaster models of every patient they were scanned with an extraoral scanner (Zfx Evolution, Zimmer Biomet Dental) (group 1). Moreover, digital impressions were made with an intraoral scanner (Trios Color POD, Phibo, 3Shape) and contacts were also registered (group 2). Finally, T-Scan III records were made and stored for further analysis (group 3). Two previously calibrated examiners independently evaluated the interocclusal contacts from every group. Data was analyzed by using Kappa index test and Pearson's chi-square test. Diagnostic tests and ROC curve were also performed. Results: Kappa interoperator index was 70.6% (better agreement). In Kappa intraoperator index, the best value was obtained in the intraoral scanner group (moderate agreement) and the worst with T-Scan III group (low agreement). ROC curve showed highest values in the intraoral scanner group (0.817) and lowest values in the T-Scan III group (0.613). Conclusion: Results suggest greater reliability to record occlusal contacts with the intraoral scanner. Clinical relevance: Intraoral scanners seem to be reliable in registering intermaxillary occlusal contacts when compared with the current gold standard.en
dc.description.departmentDepto. de Odontología Conservadora y Prótesis
dc.description.facultyFac. de Odontología
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationFraile C, Ferreiroa A, Romeo M, Alonso R, Pradíes G. Clinical study comparing the accuracy of interocclusal records, digitally obtained by three different devices. Clin Oral Investig. 2022 Feb;26(2):1957-1962. doi: 10.1007/s00784-021-04174-2. Epub 2021 Sep 14. Erratum in: Clin Oral Investig. 2022 Jun;26(6):4673. PMID: 34519908.
dc.identifier.doi10.1007/s00784-022-04542-6
dc.identifier.issn4663–4668
dc.identifier.officialurlhttps//doi.org/10.1007/s00784-022-04542-6
dc.identifier.pmid34519908
dc.identifier.relatedurlhttps://link-springer-com.bucm.idm.oclc.org/journal/784
dc.identifier.urihttps://hdl.handle.net/20.500.14352/96931
dc.issue.number2
dc.journal.titleClinical Oral Investigations
dc.language.isoeng
dc.page.final1962
dc.page.initial1957
dc.publisherSpringer
dc.rights.accessRightsopen access
dc.subject.cdu616.314-089.28
dc.subject.keywordArticulating paper T-Scan III
dc.subject.keywordExtraoral scanner
dc.subject.keywordIntraoral scanner
dc.subject.keywordOcclusal contacts
dc.subject.keywordT-Scan III
dc.subject.ucmPrótesis dental
dc.subject.unesco3299 Otras Especialidades Médicas
dc.titleClinical study comparing the accuracy of interocclusal records, digitally obtained by three diferent devicesen
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number26
dspace.entity.typePublication
relation.isAuthorOfPublicationf030d94e-3831-4893-8dd4-96421293401b
relation.isAuthorOfPublication7841c848-e37e-4d3c-ab72-647257e8de49
relation.isAuthorOfPublication1f9c3f08-3382-454f-8c0e-b5de6a5d271b
relation.isAuthorOfPublication.latestForDiscoveryf030d94e-3831-4893-8dd4-96421293401b

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Clinical study comparing.pdf
Size:
686.01 KB
Format:
Adobe Portable Document Format

Collections