Clinical study comparing the accuracy of interocclusal records, digitally obtained by three diferent devices

Loading...
Thumbnail Image
Full text at PDC
Publication date

2021

Advisors (or tutors)
Editors
Journal Title
Journal ISSN
Volume Title
Publisher
Springer
Citations
Google Scholar
Citation
Fraile C, Ferreiroa A, Romeo M, Alonso R, Pradíes G. Clinical study comparing the accuracy of interocclusal records, digitally obtained by three different devices. Clin Oral Investig. 2022 Feb;26(2):1957-1962. doi: 10.1007/s00784-021-04174-2. Epub 2021 Sep 14. Erratum in: Clin Oral Investig. 2022 Jun;26(6):4673. PMID: 34519908.
Abstract
Objective: The aim of the present cross-sectional study was to compare the interocclusal contact records obtained by three different digital methods (intra- and extraoral digital scanners and T-Scan III system) with the conventional method (articulating paper). Materials and methods: Twenty-five healthy volunteers were selected. As a control group, maximum intercuspation occlusal contacts were registered and photographed from the patients with an 8 µm articulating paper. Then, intraoral conventional elastomer impressions were taken and after obtaining the corresponding plaster models of every patient they were scanned with an extraoral scanner (Zfx Evolution, Zimmer Biomet Dental) (group 1). Moreover, digital impressions were made with an intraoral scanner (Trios Color POD, Phibo, 3Shape) and contacts were also registered (group 2). Finally, T-Scan III records were made and stored for further analysis (group 3). Two previously calibrated examiners independently evaluated the interocclusal contacts from every group. Data was analyzed by using Kappa index test and Pearson's chi-square test. Diagnostic tests and ROC curve were also performed. Results: Kappa interoperator index was 70.6% (better agreement). In Kappa intraoperator index, the best value was obtained in the intraoral scanner group (moderate agreement) and the worst with T-Scan III group (low agreement). ROC curve showed highest values in the intraoral scanner group (0.817) and lowest values in the T-Scan III group (0.613). Conclusion: Results suggest greater reliability to record occlusal contacts with the intraoral scanner. Clinical relevance: Intraoral scanners seem to be reliable in registering intermaxillary occlusal contacts when compared with the current gold standard.
Research Projects
Organizational Units
Journal Issue
Description
UCM subjects
Keywords
Collections