Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Agreement between central corneal thickness measured using pentacam, ultrasound pachymetry, specular microscopy and optic biometer lenstar LS 900 and the influence of intraocular pressure

dc.contributor.authorBorrego Sanz, Lara
dc.contributor.authorSaenz Frances, Federico
dc.contributor.authorBermudez Vallecilla, M. C.
dc.contributor.authorMorales Fernández, Laura
dc.contributor.authorMartínez De La Casa Fernández-Borrella, José María
dc.contributor.authorSantos Bueso, Enrique
dc.contributor.authorJañez Escalada, Luis
dc.contributor.authorGarcía Feijoo, Julián
dc.dateReceived: March 26, 2013 / Accepted after revision: September 20, 2013 / Published online: March 13, 2014
dc.date.accessioned2023-06-19T15:06:46Z
dc.date.available2023-06-19T15:06:46Z
dc.date.issued2014-05
dc.description.abstractPurpose: To compare central corneal thickness (CCT) values obtained by Lenstar (LE), Pentacam (PC), specular microscopy (SM) and ultrasound pachymetry (UP) in healthy corneas and study their influence on intraocular pressure (IOP) readings determined by Goldmann applanation tonometry (GAT). Methods: CCT was measured in 76 healthy subjects by LE, PC, SM and UP. We established Lin's concordance correlation coefficient (ρ-C) between different techniques. The influence of CCT on GAT was established through univariate linear regression models, IOP being the dependent variable. Results: The highest ρ-C was found between LE and SM at 0.94 (95% CI: 0.91-0.96) and between LE and UP at 0.95 (95% CI: 0.94-0.97). IOP readings showed less variability when CCT was determined using LE (7.7%, B = 0.16; 95% CI: 0.004-0.28). Conclusions: Although CCT values obtained with UP, PC, SM and LE show good correlation, these methods are not completely interchangeable. The amount of IOP variation differs when CCT is determined using LE or SM.en
dc.description.departmentUnidad Docente de Inmunología, Oftalmología y ORL
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.sponsorshipRed Telemática de Investigación Cooperativa
dc.description.sponsorshipInstituto de Salud Carlos III
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/40863
dc.identifier.citationBorrego Sanz, L., Saenz Frances, F., Bermudez Vallecilla, M. C. et al. «Agreement between Central Corneal Thickness Measured Using Pentacam, Ultrasound Pachymetry, Specular Microscopy and Optic Biometer Lenstar LS 900 and the Influence of Intraocular Pressure». Ophthalmologica, vol. 231, n.o 4, marzo de 2014, pp. 226-35. Silverchair, https://doi.org/10.1159/000356724.
dc.identifier.doi10.1159/000356724
dc.identifier.issn0030-3755
dc.identifier.officialurlhttp://dx.doi.org/10.1159/000356724
dc.identifier.urihttps://hdl.handle.net/20.500.14352/35360
dc.issue.number4
dc.journal.titleOphthalmologica
dc.language.isoeng
dc.page.final235
dc.page.initial226
dc.publisherKarger
dc.relation.projectIDRD07/0062: Patología ocular del envejecimiento, calidad visual y calidad de vida
dc.rights.accessRightsrestricted access
dc.subject.cdu617.7-089.243
dc.subject.cdu617.713
dc.subject.keywordCentral corneal thickness
dc.subject.keywordIntraocular pressure
dc.subject.keywordLenstar
dc.subject.keywordSpecular microscopy
dc.subject.ucmOftalmología
dc.subject.ucmLentes de contacto
dc.subject.ucmÓptica oftálmica
dc.subject.unesco3201.09 Oftalmología
dc.subject.unesco3311.11 Instrumentos ópticos
dc.titleAgreement between central corneal thickness measured using pentacam, ultrasound pachymetry, specular microscopy and optic biometer lenstar LS 900 and the influence of intraocular pressureen
dc.typejournal article
dc.volume.number231
dspace.entity.typePublication
relation.isAuthorOfPublication273a99c3-2c9f-4dd0-8939-b7ff3593124c
relation.isAuthorOfPublication558b8023-6d72-4dff-9f99-2e60f6f31843
relation.isAuthorOfPublication.latestForDiscovery558b8023-6d72-4dff-9f99-2e60f6f31843

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
agreement between-opthalmologica-2014.pdf
Size:
486.55 KB
Format:
Adobe Portable Document Format

Collections