An array-based electrochemical magneto-immunosensor for early neonatal sepsis diagnostic: Fast and accurate determination of C-reactive protein in whole blood and plasma samples

dc.contributor.authorMolinero-Fernández, Águeda
dc.contributor.authorMoreno Guzmán, María
dc.contributor.authorLópez, Miguel Ángel
dc.contributor.authorEscarpa, Alberto
dc.date.accessioned2024-01-15T11:05:46Z
dc.date.available2024-01-15T11:05:46Z
dc.date.issued2020-05-04
dc.description.abstractAn array-based electrochemical magneto-immunosensor (a-EMI) constituted by eight screen-printed carbon electrodes is proposed for the determination of C-reactive protein (CRP). Remarkably, the analytical usefulness of the approach was demonstrated not only by analyzing whole blood samples, but plasma ones from newborns with suspicion of sepsis, which sample volume is hardly available. The a-EIM enabled the accurate determination of CRP in these unique samples (Er < 3%) with excellent intra (CV<4%, n=8) and inter-assays (CV<9%, n=8) precision, using only 5 µL of clinical sample, covering the sepsis diagnostic range and employing only 15 min for total assay. The electrode array enabled to work with up to 8 tailored dilutions simultaneously accordingly to the CRP clinical diagnostic range. It constitutes by itself a valuable advantage for speed and reliability improvements in the sample analysis and further sepsis diagnosis. These results non-only highly met the clinical needs for sepsis newborns diagnosis, but they opened new perspectives in low volumes-based diagnostics.
dc.description.departmentDepto. de Química en Ciencias Farmacéuticas
dc.description.facultyCAI Ciencias de la Tierra y Arqueometría
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.doi10.1016/j.microc.2020.104913
dc.identifier.issn0026-265X
dc.identifier.officialurlhttps://www.sciencedirect.com/science/article/pii/S0026265X20306937
dc.identifier.urihttps://hdl.handle.net/20.500.14352/93025
dc.journal.titleMicrochemical Journal
dc.language.isoeng
dc.page.initial104913
dc.publisherElsevier
dc.rights.accessRightsrestricted access
dc.subject.ucmCiencias
dc.subject.unesco2301 Química Analítica
dc.titleAn array-based electrochemical magneto-immunosensor for early neonatal sepsis diagnostic: Fast and accurate determination of C-reactive protein in whole blood and plasma samples
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number157
dspace.entity.typePublication
relation.isAuthorOfPublication96968530-a80d-4987-a341-f4a96697f66c
relation.isAuthorOfPublication.latestForDiscovery96968530-a80d-4987-a341-f4a96697f66c
Download
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1-s2.0-S0026265X20306937-main.pdf
Size:
3.87 MB
Format:
Adobe Portable Document Format
Collections