Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Changes in Optical Quality Induced by Tilt and Decentration of a Trifocal IOL and a Novel Extended Depth of Focus IOL in Eyes with Corneal Myopic Ablations

dc.contributor.authorRuiz Alcocer, Javier
dc.contributor.authorMartínez Alberquilla, Irene
dc.contributor.authorRementería Capelo, Laureano A
dc.contributor.authorGracia Pacheco, Pablo de
dc.contributor.authorLorente Velázquez, Amalia
dc.date.accessioned2023-06-16T14:15:57Z
dc.date.available2023-06-16T14:15:57Z
dc.date.issued2021-08-01
dc.descriptionSubmitted: February 19, 2021 / Accepted: April 30, 2021 / Published Online: August 01, 2021.
dc.description.abstractPURPOSE: To assess the effect of decentration and tilt combined with prior myopic ablations on the optical performance of a trifocal intraocular lens (IOL) and a novel IOL with an extended depth of focus (EDOF) design. METHODS: The XACT Mono-EDOF ME4 (Santen Pharmaceutical Co Ltd) and the trifocal FineVision (PhysIOL) IOLs were analyzed with and without simulated previous myopic ablations. The optical quality of the IOLs was evaluated with the PMTF optical bench (LAMBDA-X). The through-focus modulation transfer function (MTF) curves were recorded. Measurements were done for three situations: centered, 0.4 mm decentered, and 4 degrees tilted. RESULTS: The trifocal IOL showed three peaks of vision and the EDOF IOL showed a far distance peak with intermediate addition. When decentration or tilt were induced, the trifocal IOL showed negligible changes but the EDOF IOL showed a -0.50 diopters (D) shift of the overall curve. With simulated myopic ablation, the trifocal IOL showed a -0.50 D shift of the curve. When tilt or decentration were also induced, the better optical results were found at -1.00 D. With myopic ablations, the EDOF IOL showed a -0.50 D shift of the optical quality and when decentration or tilt were then induced, negative shifts over -1.00 D were found. CONCLUSIONS: The trifocal IOL was less affected by misalignments. When myopic ablations were induced, both lenses decreased their optical quality and the effects of misalignments were higher. In patients who have undergone corneal myopic ablation procedures, proper alignment of the implanted IOL and obtaining effective emmetropia becomes even more critical.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.sponsorshipUniversidad Complutense de Madrid/Banco de Santander
dc.description.sponsorshipBanco Santander
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/67800
dc.identifier.doi10.3928/1081597X-20210518-03
dc.identifier.issn1081-597X
dc.identifier.officialurlhttps://doi.org/10.3928/1081597X-20210518-03
dc.identifier.relatedurlhttp://www.journalofrefractivesurgery.com/
dc.identifier.urihttps://hdl.handle.net/20.500.14352/4429
dc.issue.number8
dc.journal.titleJournal of Refractive Surgery
dc.language.isoeng
dc.page.final537
dc.page.initial532
dc.publisherSlack Incorporated
dc.relation.projectID(CT63/19-CT64/19)
dc.rights.accessRightsrestricted access
dc.subject.cdu617.7‑089.243
dc.subject.cdu617.753.2
dc.subject.cdu681.73
dc.subject.keywordCornea
dc.subject.keywordHumans
dc.subject.keywordIntraocular lenses
dc.subject.keywordMyopia
dc.subject.keywordProsthesis Design
dc.subject.keywordOcular vision
dc.subject.keywordHuman
dc.subject.keywordLens implant
dc.subject.keywordProsthesis design
dc.subject.keywordVision
dc.subject.ucmOptometría
dc.subject.ucmÓptica oftálmica
dc.subject.unesco2209.15 Optometría
dc.titleChanges in Optical Quality Induced by Tilt and Decentration of a Trifocal IOL and a Novel Extended Depth of Focus IOL in Eyes with Corneal Myopic Ablations
dc.typejournal article
dc.volume.number37
dspace.entity.typePublication
relation.isAuthorOfPublicatione7b1d7df-7032-4d5e-b1c5-ac67a61a8b1c
relation.isAuthorOfPublication7d72044d-983a-4b5a-abab-6a5e45396824
relation.isAuthorOfPublicationf7b511b2-3096-4762-909a-330bed4c0489
relation.isAuthorOfPublication.latestForDiscoverye7b1d7df-7032-4d5e-b1c5-ac67a61a8b1c

Download

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
1081597X-20210518-03.pdf
Size:
760.6 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
Manuscript JRS v.2.pdf
Size:
99.24 KB
Format:
Adobe Portable Document Format

Collections