Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Radiation tolerant isolation amplifiers for temperature measurement

dc.contributor.authorZong, Yi
dc.contributor.authorFranco Peláez, Francisco Javier
dc.contributor.authorAgapito Serrano, Juan Andrés
dc.contributor.authorFernandes, Ana C.
dc.contributor.authorMarques, José G.
dc.date.accessioned2023-06-20T10:50:28Z
dc.date.available2023-06-20T10:50:28Z
dc.date.issued2006-09-29
dc.description© 2006 Elsevier.
dc.description.abstractThis paper concentrates on the selection of radiation tolerant isolation amplifiers, which are suitable for the signal conditioners for cryogenic system in the Large Hadron Collider (LHC). The evolution and the results of different commercial isolation amplifiers’ parameters under neutron and gamma radiation are presented. In most cases, the tested isolation amplifiers’ input offset voltage, bias currents and output offset voltage hardly changed during the radiation. The \{DC\} gain in input stage was only affected for some isolation amplifiers with a small open loop gain. Transmission coefficient showed decrease for all the tested isolation amplifiers. Also, the \{DC\} output voltage increased and the ripple voltage decreased for all the build-in isolated regulators. In addition, results on 1B41 signal conditioner showed that it was tolerant to 7–8×1012 n/cm2, which was 50\% higher than the expected dose in the LHC.
dc.description.departmentDepto. de Estructura de la Materia, Física Térmica y Electrónica
dc.description.facultyFac. de Ciencias Físicas
dc.description.refereedTRUE
dc.description.sponsorshipMinisterio de Educación y Ciencia
dc.description.sponsorshipCERN
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/28868
dc.identifier.doi10.1016/j.nima.2006.09.007
dc.identifier.issn0168-9002
dc.identifier.officialurlhttp://www.sciencedirect.com/science/article/pii/S0168900206015774
dc.identifier.urihttps://hdl.handle.net/20.500.14352/51319
dc.issue.number2
dc.journal.titleNuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
dc.language.isoeng
dc.page.final876
dc.page.initial869
dc.publisherElsevier Science BV
dc.relation.projectIDFPA2002-00912
dc.relation.projectIDK476/LHC
dc.rights.accessRightsopen access
dc.subject.cdu537.8
dc.subject.keywordCOTS
dc.subject.keywordIsolation amplifiers
dc.subject.keywordRadiation damage
dc.subject.ucmElectrónica (Física)
dc.subject.ucmRadiactividad
dc.titleRadiation tolerant isolation amplifiers for temperature measurement
dc.typejournal article
dc.volume.number568
dspace.entity.typePublication
relation.isAuthorOfPublication662ba05f-c2fc-4ad7-9203-36924c80791a