Para depositar en Docta Complutense, identifícate con tu correo @ucm.es en el SSO institucional: Haz clic en el desplegable de INICIO DE SESIÓN situado en la parte superior derecha de la pantalla. Introduce tu correo electrónico y tu contraseña de la UCM y haz clic en el botón MI CUENTA UCM, no autenticación con contraseña.
 

Radiation tolerant isolation amplifiers for temperature measurement

Loading...
Thumbnail Image

Full text at PDC

Publication date

2006

Advisors (or tutors)

Editors

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier Science BV
Citations
Google Scholar

Citation

Abstract

This paper concentrates on the selection of radiation tolerant isolation amplifiers, which are suitable for the signal conditioners for cryogenic system in the Large Hadron Collider (LHC). The evolution and the results of different commercial isolation amplifiers’ parameters under neutron and gamma radiation are presented. In most cases, the tested isolation amplifiers’ input offset voltage, bias currents and output offset voltage hardly changed during the radiation. The \{DC\} gain in input stage was only affected for some isolation amplifiers with a small open loop gain. Transmission coefficient showed decrease for all the tested isolation amplifiers. Also, the \{DC\} output voltage increased and the ripple voltage decreased for all the build-in isolated regulators. In addition, results on 1B41 signal conditioner showed that it was tolerant to 7–8×1012 n/cm2, which was 50\% higher than the expected dose in the LHC.