Dosimetric study of bevel factors in IOERT with mobile linacs: towards a unified code of practice

dc.contributor.authorAyala, Rafael
dc.contributor.authorGarcía, Rocío
dc.contributor.authorRuiz, Gema
dc.contributor.authorGarcía, María Jesús
dc.contributor.authorSoza, Álvaro
dc.contributor.authorGómez, Susana
dc.contributor.authorUdías Moinelo, José Manuel
dc.contributor.authorIbáñez García, Paula Beatriz
dc.date.accessioned2026-04-21T18:56:22Z
dc.date.available2026-04-21T18:56:22Z
dc.date.issued2024-11
dc.description© 2024 Associazione Italiana di Fisica Medica e Sanitaria.
dc.description.abstractBackground: Dosimetry in intraoperative electron radiotherapy (IOERT) poses distinct challenges, especially with inclined applicators deviating from international protocols. Ion recombination in ionization chambers, electron beam degradation due to scattering in cylindrical applicators, coupled with a lack of a welldefined beam quality surrogate, complicate output factor determination with ionization chambers. Synthetic diamond-based detectors, offer potential solutions; however, their suitability requires further exploration. Purpose: This study addresses output factor determination for beveled applicators. Objectives include assessing the suitability of PTW microDiamond detectors and determining correction factors for ionization chamber measurements based on energy variations at the depth of maximum dose ( z max ) for beveled applicators. Experimental data are compared against results obtained from Monte Carlo simulations. Methods: We conducted measurements using both PTW microDiamond and IBA CC01 detectors. In addition to benchmarking bevel factors with penEasy, we employed Monte Carlo simulations to determine angular response correction factors for microDiamond detectors and to evaluate energy variations at z max for beveled applicators. Results: The findings indicate that angular response correction factors are unnecessary for microDiamond detectors with beveled applicators. However, variations in mean energy at z max potentially impact absorbed dose calculations with ionization chambers, particularly with the most inclined applicators. Conclusions: Based on our results, the study recommends using microDiamond detectors over cylindrical ionization chambers for output factor determination in IOERT with inclined applicators. Addressing energy variations at z max is crucial to improve accuracy in ionization chamber measurements. These findings have implications for dosimetry protocols in IOERT, contributing to enhanced delivery in clinical practice.
dc.description.departmentDepto. de Estructura de la Materia, Física Térmica y Electrónica
dc.description.facultyFac. de Ciencias Físicas
dc.description.facultyInstituto de Física de Partículas y del Cosmos (IPARCOS)
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationAyala R, García R, Ruiz G, García MJ, Soza Á, Gómez S, et al. Dosimetric study of bevel factors in IOERT with mobile linacs: Towards a unified code of practice. Physica Medica 2024;127:104836. https://doi.org/10.1016/j.ejmp.2024.104836.
dc.identifier.doi10.1016/j.ejmp.2024.104836
dc.identifier.essn1724-191X
dc.identifier.issn1120-1797
dc.identifier.officialurlhttps://doi.org/10.1016/j.ejmp.2024.104836
dc.identifier.relatedurlhttps://www.sciencedirect.com/science/article/pii/S1120179724010937?via%3Dihub
dc.identifier.urihttps://hdl.handle.net/20.500.14352/134947
dc.journal.titlePhysica Medica
dc.language.isoeng
dc.page.final104836-11
dc.page.initial104836-1
dc.publisherElsevier
dc.rights.accessRightsopen access
dc.subject.cdu61
dc.subject.cdu53
dc.subject.keywordIOERT
dc.subject.keywordBevel applicators
dc.subject.keywordIORT
dc.subject.keywordElectron radiotherapy
dc.subject.keywordMobile linacs
dc.subject.keywordMonte Carlo
dc.subject.ucmCiencias Biomédicas
dc.subject.unesco22 Física
dc.titleDosimetric study of bevel factors in IOERT with mobile linacs: towards a unified code of practice
dc.typejournal article
dc.type.hasVersionSMUR
dc.volume.number127
dspace.entity.typePublication
relation.isAuthorOfPublication3dc23e23-6e7e-47dd-bd61-8b6b7a1ad75f
relation.isAuthorOfPublication3e87aa6b-a8b0-482e-99ba-f8afc04e5340
relation.isAuthorOfPublication.latestForDiscovery3dc23e23-6e7e-47dd-bd61-8b6b7a1ad75f

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
bevel_factors (1).pdf
Size:
12.75 MB
Format:
Adobe Portable Document Format

Collections