Para depositar en Docta Complutense, identifícate con tu correo @ucm.es en el SSO institucional. Haz clic en el desplegable de INICIO DE SESIÓN situado en la parte superior derecha de la pantalla. Introduce tu correo electrónico y tu contraseña de la UCM y haz clic en el botón MI CUENTA UCM, no autenticación con contraseña.

Approximate methods to determine the modulation transfer function of a hololens system: a comparative study

Loading...
Thumbnail Image

Full text at PDC

Publication date

1995

Advisors (or tutors)

Editors

Journal Title

Journal ISSN

Volume Title

Publisher

Spie-Soc Photo-Optical Instrumentation Engineers
Citations
Google Scholar

Citation

Abstract

We present a comparative study between two experimental methods to determine the modulation transfer function (MTF) of a hololens system. The two hololenses were previously recorded and tested for filtering pseudocolor. In the first method we used the classical Foucault test. The second, alternative method is based on the digital image processing of a perfect edge under incoherent illumination. From the digitized intensity line profiles we obtain the MTF and cutoff frequency of the optical system according to the reciprocity between line spread function and MTF. Comments are made on the applicability and accuracy of these two methods.

Research Projects

Organizational Units

Journal Issue

Description

© 2005 COPYRIGHT SPIE--The International Society for Optical Engineering.