Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Design of electrochemical immunosensors using electro-click chemistry. Application to the detection of IL-1β cytokine in saliva

dc.contributor.authorGuerrero Irigoyen, Sara
dc.contributor.authorAgüí Chicharro, María Lourdes
dc.contributor.authorYáñez-Sedeño Orive, Paloma
dc.contributor.authorPingarrón Carrazón, José Manuel
dc.date.accessioned2024-01-11T18:39:54Z
dc.date.available2024-01-11T18:39:54Z
dc.date.issued2020
dc.description.abstractElectro-click methodology was employed to prepare an electrochemical immunosensor for the cytokine interleukin 1β (IL-1β). The strategy involved binding of ethynylated IgG to azide-MWCNTs modified electrodes by Cu(I) catalyzed-cycloaddition reaction where the catalyst was electrochemically synthesized. This electro-click protocol is significantly faster and greener than the methods for catalyst generation through chemical reduction. The oriented immobilization of the capture antibody onto IgG-MWCNTs conjugates allowed the preparation of a sandwich-type immunosensor using biotinylated anti-IL-1β as detector antibody labeled with alkaline phosphatase-streptavidin (AP-strept). Differential pulse voltammetric transduction through the 1-naphthylphosphate/1-naphthol system was carried out. The analytical characteristics achieved with the electrochemical immunosensor showed a calibration curve exhibiting two linear ranges between 10 and 200 pg mL−1 (r2 = 0.998), and from 200 to 1200 pg mL−1 (r2 = 0.998), and a LOD value of 5.2 pg mL−1, an improvement compared with those claimed for commercial ELISA kits. In addition, the assay time was at least one hour shorter. Excellent performance was observed in the determination of IL-1β in saliva with no need for sample treatment, and by simple interpolation using a calibration plot constructed with standard solutions of the target cytokine.
dc.description.departmentDepto. de Química Analítica
dc.description.facultyFac. de Ciencias Químicas
dc.description.refereedTRUE
dc.description.sponsorshipMinisterio de Economía y Competitividad (España)
dc.description.sponsorshipMinisterio de Ciencia, Innovación y Universidades (España)
dc.description.sponsorshipComunidad de Madrid
dc.description.statuspub
dc.identifier.citationGuerrero S, Agüí L, Yáñez-Sedeño P, Pingarrón JM. Design of electrochemical immunosensors using electro-click chemistry. Application to the detection of IL-1β cytokine in saliva. Bioelectrochemistry. 2020 Feb 14;133:107484 - 107490.
dc.identifier.doi10.1016/j.bioelechem.2020.107484
dc.identifier.essn1567-5394
dc.identifier.issn1878-562X
dc.identifier.officialurlhttps://doi.org/10.1016/j.bioelechem.2020.107484
dc.identifier.pmid32087557
dc.identifier.urihttps://hdl.handle.net/20.500.14352/92649
dc.journal.titleBioelectrochemistry
dc.language.isoeng
dc.page.final107490
dc.page.initial107484
dc.publisherElsevier
dc.relation.projectIDCTQ2015-64402-C2-1-R
dc.relation.projectIDRTI2018-096135- B-I00
dc.relation.projectIDP2018/NMT-4349
dc.rightsAttribution-NonCommercial 4.0 Internationalen
dc.rights.accessRightsrestricted access
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/
dc.subject.cdu543
dc.subject.cdu544.6:543.25
dc.subject.cdu543.25:544.6
dc.subject.keywordClick chemistry
dc.subject.keywordElectro-click
dc.subject.keywordElectrochemical immunosensor
dc.subject.keywordInterleukin 1b
dc.subject.keywordIL-1b
dc.subject.keywordCytokine
dc.subject.keywordSaliva
dc.subject.keywordBiomarker
dc.subject.keywordInflammation
dc.subject.ucmQuímica analítica (Química)
dc.subject.unesco2301 Química Analítica
dc.subject.unesco2301.04 Análisis Electroquímico
dc.titleDesign of electrochemical immunosensors using electro-click chemistry. Application to the detection of IL-1β cytokine in saliva
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number133
dspace.entity.typePublication
relation.isAuthorOfPublication746c8c8c-1e81-4897-8b4f-bfb1ff9d741a
relation.isAuthorOfPublicationba1cfa29-0064-4c8d-9c24-b0093bfe6d0a
relation.isAuthorOfPublication06ab2fa0-2b2d-4b58-80ed-82f9cc767175
relation.isAuthorOfPublication8808f99c-5f56-4562-839a-517626c76dad
relation.isAuthorOfPublication.latestForDiscovery746c8c8c-1e81-4897-8b4f-bfb1ff9d741a

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Design_of_electrochemical_immunosensors.pdf
Size:
818.28 KB
Format:
Adobe Portable Document Format

Collections