Para depositar en Docta Complutense, identifícate con tu correo @ucm.es en el SSO institucional. Haz clic en el desplegable de INICIO DE SESIÓN situado en la parte superior derecha de la pantalla. Introduce tu correo electrónico y tu contraseña de la UCM y haz clic en el botón MI CUENTA UCM, no autenticación con contraseña.

Preliminary test for radiation tolerant electronic components for the LHC cryogenic system

Citation

Abstract

The LHC accelerator will use about 1600 main superconducting magnets operating below 2K. The magnets temperature is a control parameter and its target accuracy imposes very severe constraints on both the sensing element and its signal conditioner. They will both be installed inside the tunnel, thus exposed to a relatively high neutron fluence and gamma dose. It is then crucial to understand the effects of radiation on the performance of the electronic components that will be selected for the signal conditioner. This paper presents data concerning the radiation effects on typical active and passive discrete electronic components. This is the first step toward building a radiation tolerant signal conditioner.

Research Projects

Organizational Units

Journal Issue

Description

© CERN Workshop on Electronics for LHC Experiments (5. 1999. Snowmass, Colorado). This work has been financed by the cooperation agreement K476/LHC between CERN & UCM and by the Spanish research agency CICYT (TIC98-0737), and partially supported by ITN.

Unesco subjects

Keywords