Retinal nerve fiber layer thickness in children with primary congenital glaucoma measured by spectral domain optical coherence tomography
Loading...
Official URL
Full text at PDC
Publication date
2019
Advisors (or tutors)
Editors
Journal Title
Journal ISSN
Volume Title
Publisher
Elsevier
Citation
Perucho González, L., Martínez De La Casa Fernández-Borrella, J. M., Sáenz Francés, F. et al. «Retinal Nerve Fiber Layer Thickness in Children with Primary Congenital Glaucoma Measured by Spectral Domain Optical Coherence Tomography». Journal of American Association for Pediatric Ophthalmology and Strabismus, vol. 23, n.o 2, abril de 2019, p. 94.e1-94.e4. DOI.org (Crossref), https://doi.org/10.1016/j.jaapos.2017.03.023.
Abstract
Purpose: To evaluate retinal nerve fiber layer (RNFL) thickness using spectral domain optical coherence tomography (SD-OCT) in a population of children diagnosed with primary congenital glaucoma (PCG).
Methods: In this cross-sectional study, 59 eyes of 59 children diagnosed with PCG and 87 eyes of 87 healthy children were evaluated by SD-OCT to measure the RNFL. The global average peripapillary RNFL thickness and sectional RNFL thickness were evaluated in both groups. Differences in global average and sectional thickness were analyzed.
Results: Mean age in the PCG group was 9.61 ± 3.23 years; in the control group, 8.47 ± 2.99 years (P = 0.0516). There were statistically significant differences (P < 0.007) in all sectors between both groups.