Influence of Instrumental Factors in the Measurement of Power Profiles of Intraocular Lenses with a Commercial Deflectometer

dc.contributor.authorGómez Pedrero, José Antonio
dc.contributor.authorAlbarrán Diego, César
dc.contributor.authorGarcía Montero, María
dc.contributor.authorGarzón Jiménez, Nuria
dc.contributor.authorGonzález Fernández, Verónica
dc.date.accessioned2023-11-15T17:41:40Z
dc.date.available2023-11-15T17:41:40Z
dc.date.issued2023-08-31
dc.description.abstractDeflectometry is an optical technique for determining properties such as power distribution, wavefront, etc., and measurement of the optical properties of an intraocular lens can provide relevant information for clinicians. The aim of the current study was to establish a protocol for measuring lens power maps and profiles of various optical designs of intraocular lenses with a deflectometer based on the phase-shifting Schlieren principle (NIMO TR1504, Lambda-X, Nivelles, Belgium). The results are discussed with respect to accuracy and repeatability, the influence of the use of filters, and whether to consider the intraocular lens as a thin or thick lens.en
dc.description.departmentDepto. de Óptica
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.sponsorshipAgencia Estatal de Investigación (España)
dc.description.statuspub
dc.identifier.citationGómez Pedrero, J. A., Albarrán Diego, C., García Montero, M. et al. «Influence of Instrumental Factors in the Measurement of Power Profiles of Intraocular Lenses with a Commercial Deflectometer». Applied Sciences, vol. 13, n.o 17, agosto de 2023, p. 9882. DOI.org (Crossref), https://doi.org/10.3390/app13179882.
dc.identifier.doi10.3390/app13179882
dc.identifier.essn2076-3417
dc.identifier.officialurlhttps://doi.org/10.3390/app13179882
dc.identifier.urihttps://hdl.handle.net/20.500.14352/88732
dc.issue.number9882
dc.journal.titleApplied Sciences
dc.language.isoeng
dc.page.total15
dc.publisherMDPI
dc.relation.projectIDPID2021-122486OA-I00
dc.rightsAttribution 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subject.cdu617.7-089.243
dc.subject.cdu681.73
dc.subject.cdu617.75
dc.subject.keywordIntraocular lens
dc.subject.keywordDeflectometry
dc.subject.keywordPower profile
dc.subject.ucmÓptica y optometría
dc.subject.ucmÓptica geométrica e instrumental
dc.subject.unesco2209 Óptica
dc.subject.unesco3311.09 Lentes
dc.subject.unesco2209.15 Optometría
dc.titleInfluence of Instrumental Factors in the Measurement of Power Profiles of Intraocular Lenses with a Commercial Deflectometer
dc.typejournal article
dc.type.hasVersionAM
dc.volume.number13
dspace.entity.typePublication
relation.isAuthorOfPublication5c5cb6be-771c-40ed-8af0-cdfdbdfb3d36
relation.isAuthorOfPublication9b637d56-481e-40c6-a0e6-eb4de92e663c
relation.isAuthorOfPublication367ce491-287f-4b2a-ba6a-870a393c5609
relation.isAuthorOfPublicationaa913134-98ab-438d-b8ac-14620d5e3261
relation.isAuthorOfPublication367ce491-287f-4b2a-ba6a-870a393c5609
relation.isAuthorOfPublication.latestForDiscoveryaa913134-98ab-438d-b8ac-14620d5e3261
Download
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
applsci-13-09882-v2.pdf
Size:
2.67 MB
Format:
Adobe Portable Document Format
Collections